    Looking for a diverter to operate 2 separate shower heads?
    I am are looking for a diverter to operate 2 shower heads, regular shower head and waterfall shower head that is mounted from the ceiling. I would like to have the option to use either shower head or both shower heads at the same time. Is there a diverter that you can do this with?
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #2

    Jan 16, 2011, 06:20 PM

    Is this a tube or a shower stall? Any brand names or models for this water fall, sounds like a rain shower.
    Milo Dolezal's Avatar
    Milo Dolezal Posts: 7,192, Reputation: 523
    Plumbing Expert
     
    #3

    Jan 17, 2011, 01:50 PM

    There is number of diverter valves you can use. Most common are made by Delta, Grohe, HansGrohe, Kohler and more. I am not sure about valve that allows both heads to run full force at the same time. This is usually accomplished by installing 2 separate volume control valves. Back to you. Milo
    Attached Images
      
    wesconnor's Avatar
    wesconnor Posts: 4, Reputation: 1
    New Member
     
    #4

    Jan 18, 2011, 05:31 PM
    Milo, would you use 2 way diverter (if there is such a thing) or a 3 way diverter?
    wesconnor's Avatar
    wesconnor Posts: 4, Reputation: 1
    New Member
     
    #5

    Jan 18, 2011, 05:36 PM
    Comment on ballengerb1's post
    This is a walk in shower that a am currently roughing in so everything is open. There will be a rain shower head from the ceiling. I need to purchase everything for the shower yet.


    mygirlsdad77's Avatar
    mygirlsdad77 Posts: 5,713, Reputation: 339
    Plumbing Expert
     
    #6

    Jan 18, 2011, 06:00 PM

    I would suggest using two separate volume control valves and one 3/4 inch temperature control valve. In this setup(ive only installed moen) you supply the temp valve with 3/4 hot and cold, then off the top of the temp valve you supply each volume control valve with 3/4 via a tee. Then off the top of the volume valve you supply each shower head with 1/2. This way you will have enough volume to run both shower heads at once with great pressure, and the control to use either shower head separately. You could even add a third volume control and have a hand held shower or add some body sprays. Ive done quite a few of these setups with moen products and the homeowners have all had raving reviews on the systems. Just beware, the more you add, the more creative the plumbing will get to fit it all in the wall. Good luck and please let us know how it all works out.
    wesconnor's Avatar
    wesconnor Posts: 4, Reputation: 1
    New Member
     
    #7

    Jan 18, 2011, 07:12 PM
    Comment on Milo Dolezal's post
    Milo, would you use 2 way diverter (if there is such a thing) or a 3 way diverter?
    Milo Dolezal's Avatar
    Milo Dolezal Posts: 7,192, Reputation: 523
    Plumbing Expert
     
    #8

    Jan 18, 2011, 08:16 PM

    You will need 3 way diverter for your situation ( 1 Inlet (mix h/c)) and 2 outlets ).

    I am enclosing pic of shower we did recently. Left and Right sides are identical. They consists of Thermostatic valve and 3 way diverter ( 1 inlet from Thermostatic Valve, 1 stationary shower head and 1 hand-held), each side. Middle valve is regular thermostatic / volume control valve that operates Rain Shower head only. Incoming water pipes were: Cold water side 1 1/2" to each valve with 3/4" valve inlets. Hot water side was plumbed with 3/4" pipe all the way. Shower head risers were 3/4" as well. House pressure: 55 psi.

    This is the proper way of installing such a system. This way, you can run all 5 shower heads full blast and still have adequate water pressure and flow. Make sure you hire experienced plumber for such installation. Don't try to cut corners. If you do, you will regret it every time you step into the shower.

    Good luck with your project. Let me know how you did. Milo
    Attached Images
     
    mygirlsdad77's Avatar
    mygirlsdad77 Posts: 5,713, Reputation: 339
    Plumbing Expert
     
    #9

    Jan 19, 2011, 06:13 PM

    That's a nice looking setup Milo. Good job.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Shower w/o diverter. Will a diverter tub spout give me a shower and bath option? [ 4 Answers ]

Had k-t14776 and k-304-ks recently installed. Now I'm told I have no shower capability. Will purchasing a diverter tub spout give me options for both a shower and bath?

Wiring bath fan with light/fan combo. Want to operate them on separate switches. [ 1 Answers ]

I have power wire with a black/white/ ground. The switches have their own wires with Black/ White wires. The fan unit has two plugs one for the fan with a blue wire and a white wire, and the light has a black wire and a white wire.

In Search of an in-wall diverter (two shower heads) [ 5 Answers ]

Hi there everyone, I'm remodeling my bathroom, and I've run into a problem. I'm using a standard setup for the bath with a dual handle manifold which uses a stop on the tub spigot to divert flow to the shower head, but I've made a decision that has put me at a stopping point. I've plumbed...


View more questions Search