Ask Experts Questions for FREE Help !
Ask
    hopetoretire's Avatar
    hopetoretire Posts: 3, Reputation: 1
    New Member
     
    #1

    Dec 28, 2010, 12:51 AM
    Sewage Pump
    I know sewage ejectors typically lift waste to a higher lever and empty into a normal gravity flow waste line to sewer or septic. Without the ability to gravity feed any of the system due to shallow sewer, will a normal ejector pump work to pump the waste through a virtually flat waste pipe - some 150 ft? If so, should the entire run be equal to pump outlet (2")? Any suggestions are welcome. Thanks in advance.
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #2

    Dec 28, 2010, 06:44 AM

    Hi HTR...

    At a length like that, ideally, the sewer pipe needs to be pitched at 1/4" per foot of piping. You might even be able to get away with an 1/8" per foot of piping, but at anything less than 1/8" pitch per foot of piping you can be pretty sure that solids will collect over time and the drain line will plug up and need to be cleared on a regular basis.

    I would pipe it up at a minimum of 3" piping. I would also install a cleanout every 75 feet.

    Care to discuss more? If so, post your thoughts and when I pop in next I'll respond.

    Mark
    hopetoretire's Avatar
    hopetoretire Posts: 3, Reputation: 1
    New Member
     
    #3

    Dec 28, 2010, 07:11 AM
    Thanks Mass, Slope is the problem - renovating an old garment factory building on an island without plmg code enforcement. Factory waste flows to an underground tank (no discharge or leach line)- requires pump truck weekly at some cost. Sewer line now exists at front of building but is about 2 ft deep. May be able to squeeze 1/8th"/ft out of it by discharging pump as shallow as possible. Appreciate your answer - it tells me that the head pressure from ejector pump will not sustain enough pressure to push solids that distance. Seems logical - when pump shuts off, flow would end and liquids would likely mostly flow, leaving solids. Thanks again.
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #4

    Dec 28, 2010, 07:15 AM

    Have a great day!
    hopetoretire's Avatar
    hopetoretire Posts: 3, Reputation: 1
    New Member
     
    #5

    Dec 28, 2010, 07:16 AM
    Comment on massplumber2008's post
    See "answer" above - first timer - didn't see 'comment' button - thanks again!
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #6

    Dec 28, 2010, 07:21 AM

    Got you! I appreciate it!

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

My sewage pump. [ 1 Answers ]

I have a liberty pumps sewage pump. Model # 372/LE41A. I've had it since 1997 and it recently stopped working? The manual says that it could be a blown fuse, defective switch, short, switch is unable to move due to an obstacle or insufficient liquid level. I tried plunging, and the water seeps...

Is Meyers pentair sewage ejector pump model SR1830 a quality pump? [ 1 Answers ]

Just installed a sewage ejector pump and I'm somewhat concerned about the manufacture. Not seeing very much information about Meyer. I see Zoeller and Little Giant, so I'm wondering if I got a quality systems. Considering all that was required to get the system in I don't want to revisit this for...

Sewage tank pump [ 2 Answers ]

I have a sewage tank downstairs in the basement,the pump works between every 2hours or less,and at the same time we are not using the water downstairs very often as we are using the water on the main floor,I am wondering if this is normal,or if there might be something wrong with the tank.Might the...

Sewage pump windings gone? [ 1 Answers ]

We have a tank in our garden, where all our waist goes from the house. When it reaches a specific level a pump starts and pumps the waist up hill to the mains sewage system. One of our pumps isn't working at all. I've had it out and checked it over. The pump is turning freely. The only thing I...

Sewage pump/ejector pump [ 2 Answers ]

My sewage/ejector pump sometimes won't shut itself off. It has gradually gotten worse as time goes by. What could be causing this? Any suggestions appreciated.


View more questions Search