New Member
|
|
Dec 8, 2010, 03:04 AM
|
|
Priming without a foot valve
I have just bought a pump. When I took it to the mine, my team said it needs a foot valve. The cperson that sold me the pump insist its not necessary. Now I am confused. The Person who sold me the pump can only be available next week and I can't wait as it is affecting production. So which is which and can I prime without the foot valve? How do I do it
|
|
 |
Uber Member
|
|
Dec 8, 2010, 06:34 AM
|
|
Depends on whether it is a submersible pump (will be at the bottom with pipe going above it) or a jet pump (will be above ground with pipe going into the well/mine). If it is submersible, it does not need to be primed or need a footvalve. If it is a jetpump, then it will need, so far as I am aware, a foot valve.The footvalve is basically a checkvalve. Once you prime a jet pump, the footvalve prevents water from simply running down the pipe when the pump cuts off.
|
|
 |
Eternal Plumber
|
|
Dec 8, 2010, 07:32 AM
|
|
The cperson that sold me the pump insist a check valve is not necessary
Which is why big box guys are selling instead of doing. All pumps, both submersible and surface need check/foot valves,
Surface pumps install a foot valve at the well point or a check valve on then suction line next to the pump. And here's the skinny on submersible check valves. Listen to your team. I'd stack them up against a big box salesman any day of the year! Good luck, TGom
|
|
 |
Uber Member
|
|
Dec 8, 2010, 08:32 AM
|
|
Consider this: If your submersible pump is not pumping into a pressure tank, you could (maybe even should) operate it with no check valve. This allows the water to drain out of the wellpipe when the pump shuts off, allowing the pump to cut on with no head pressure, which is an advantage. In a situation in which you are draining water (a mine?), it seems to me that would work well.
At any rate, it really sounds like this guy has purchased a jet pump anyway.
|
|
 |
Eternal Plumber
|
|
Dec 8, 2010, 04:47 PM
|
|
In agree with jlisenbe,
The surface pumps must have check valves.
Consider this: If your submersible pump is not pumping into a pressure tank,
But don't most pumps discharge into a bladder or pressure tank? And even if 5they were controlling ground water in a mine when the pump shuts down would they want all the water bin the discharge line draining back into the mine shaft?
Regards, Tom
|
|
 |
Uber Member
|
|
Dec 9, 2010, 08:47 AM
|
|
Excellent point. I am thinking of a pump used for sprinklers, irrigation, or other uses where a tank is not absolutely essential. Not real sure how these mine pumps are set up or used.
|
|
 |
New Member
|
|
Dec 13, 2010, 03:28 AM
|
|
Thanks everyone for the responses. I have since realised I definitely need a foot valve. It was a Salesman who had pushed a product he wasn't familiar with. It turns out all the things he had told me the pump can do it cannot do.
|
|
 |
Eternal Plumber
|
|
Dec 13, 2010, 05:29 AM
|
|
Hey Maps,
Thanks for the update. You have just put your finger on why big box guys are selling instead of doing. Good luck, Tom
|
|
Question Tools |
Search this Question |
|
|
Add your answer here.
Check out some similar questions!
Foot pain side of foot, feels painful but better when I squeeze my foot
[ 4 Answers ]
It is midway down my right foot and only foot massage seems to apease it, but itsgetting worse and hurts earlier and earlier each evening. The central point is midway and for the ultimate in relief is to squeeze my feet down the sides, but that also sends me into agony once squeezed, but the long...
Pump is short cycling and blowing foot valve off.
[ 1 Answers ]
I woke up Saturday to no water; checked the pump into house and it was running (did not notice the short cyle at the time) so shut it off and checked holding tank. There was plenty of water but the pvc pipe that has the foot valve screwed into it was off. So let the pump cool down and put pipe...
How do you know when a foot valve needs replacing on ruthberry well pump?
[ 0 Answers ]
My hot water tank went out my son in law replaced itr and he hooked the hot water to the cold and cold to hot on top of the tank then he lit it and said I should have hot water in about an hour . In about an hour I had no water at all and my pump had lost it's
Prime and we put about 10 gallons of...
I can't get my jet pump to prime and my foot valve is working correctly
[ 1 Answers ]
5 days ago my hubby was drilling holes for a garage and hit our water line he repaired the break in the feed and return line, we tried to prime the pump and we cannot get the pressure to build like it should. We have checked to repairs to make sure they are not leaking... nothing 5 days later we...
View more questions
Search
|