    Well water pressure
    I have a well with the pump and take. I recently just had to replace the tank. Now, I have just a stream of water pressure running in the house. What can I do to fix this?
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Nov 9, 2010, 10:03 AM

    Did you set the bladder tank pressure at 2 PSI under them cut in point on the control box?
    This must be done with the pump shut off and the system bled down. Let me know if it helps. Toim
    msfri's Avatar
    msfri Posts: 2, Reputation: 1
    New Member
     
    #3

    Nov 9, 2010, 10:42 AM
    Comment on speedball1's post
    Where is that set at? On the points does those need adjusting as well?
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #4

    Nov 9, 2010, 11:03 AM

    Where is that set at?
    There's a snifter valve at the top of the tank. I've put up a picture of how bladder tanks work, ()see image).
    On the points does those need adjusting as well?
    No! The control box settings stay the same. Good luck, Tom
    Attached Images
     

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Pressure regulator works okay, but with water off, has very high back pressure [ 4 Answers ]

I went to check my home's water pressure. When I did this, it read off the charts at 100psi. Adjusting the pressure regulator did nothing apparent. But in the shower, the adjustment definitely had an affect - even thought he pressure meter didn't show a change. I tried a second pressure meter...

New Water Heater~ now no water pressure, pressure tank won't stay on... [ 1 Answers ]

Hello, Yesterday, we had our hot water heater replaced as it was 18 years old. The utility company sent their plumbing contractor to take the old one our and put in the new one. Before they arrived our water was perfectly fine. After they left, we had no water. Basically told my wife, sorry we...

New shallow well pump new huge pressure tank but water pressure is terrible [ 11 Answers ]

When I had a smaller pump (shallow well) and small tank my water pressure was great. When I had to replace everything the person installing the system put a bigger pump and a huge pressure tank. It is the size of a 50 gal water heater. I replaced everything. Ever since then my water pressure is...

Does the pressure from the hot water tank effect the pressure of the cold water? [ 2 Answers ]

We have very low water pressure at our kitchen sink from both the cold and hot water faucets, but no problem with the water pressure to the bathroom or washer. The cold water tank is closest to the kitchen and the hot water heater is near the bathroom and washer. Someone told my roommate that there...


View more questions Search