Ask Experts Questions for FREE Help !
Ask
    stickshift_dm's Avatar
    stickshift_dm Posts: 3, Reputation: 1
    New Member
     
    #1

    Oct 6, 2010, 07:45 PM
    Is it OK to have two p-traps in a tub drain?
    Is it OK to have two p-traps in a tub drain?
    I have a 2" p-trap built into plumbing in the foundation and a vent right next to the downside of that trap. I am placing a new whirlpool tub that sits right down on the floor and has a 2-1/8" deep drain kit that is below the floor line in the box formed down in the foundation for the drain connection. When I place a 2" elbow90 on the drain pipe at the lowest point and then pipe over and reduce to a 1-1/2" elbow90 with the compression fitting on top that connects to the brass down tube included in the tub drain kit I am too high, so If I use a S trap inplace of the 90-pipe-90 it lowers the compression fitting and gives me the room I need to place the drain kit below floor level. Is having this S-trap above the p-trap going to hinder or cause problems with the tub drain?
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #2

    Oct 6, 2010, 08:14 PM

    Hi Stickshift...

    As awful as it sounds, you cannot double trap a fixture and you also cannot use an strap not even by itself.

    There have been many many times that I didn't want to but I simply had to cut out the existing trap and move it so it was directly under the tub drain.

    You should also remove the floor and install the trap directly under the tub drain assembly.

    Mark
    stickshift_dm's Avatar
    stickshift_dm Posts: 3, Reputation: 1
    New Member
     
    #3

    Oct 6, 2010, 08:50 PM
    Comment on massplumber2008's post
    Thanks for the confirmation. I was concerned about the effect of double trap and can see where it would create a problem without a vent in between. I am going to search out some smaller radius 90s and find a compression fitting that sits right in
    stickshift_dm's Avatar
    stickshift_dm Posts: 3, Reputation: 1
    New Member
     
    #4

    Oct 6, 2010, 08:55 PM
    Comment on massplumber2008's post
    The elbow90 facing up without pipe and an extra fitting. If I cannot find enough there I will simply raise the tub with a 1-1/2" stone foundation to fit the drain. These would be easier than chiseling out a 1/4 yd of concrete to get to trap.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Can two traps on one tub work? [ 4 Answers ]

Can two traps on one tub work?

Washing machine drain traps [ 2 Answers ]

I am installing anew washer kenmore HE4T drain pipe I was told if the trap is to low like under the floor that the water falling that far will empty the trap . Is this true ? And do I need a vent also.

Basement drain traps [ 1 Answers ]

When I installed my floor drains in a basement with a concrete floor I totally forgot to add traps and now I am getting an odor in my basement.How can I fix this problem without breaking up the concrete.There must be some kind of a trap that could possibly fit inside a four inche pipe.This is what...

Drain traps and venting [ 1 Answers ]

We were told that the drain traps are not in the proper place and that the drains are not properly vented. What do they mean? Can this be fixed by us and how do you do it? How long will it take?

Basement drain with 2 traps [ 2 Answers ]

Hi, I'm upgrading the basement bathroom and need to move the shower drain about 8 inches. The previous shower drain came above grade just enough to clear the old concrete basin. I believe the old shower was built about the same time as the house was built, in 1956. All the old piping is 2 inch...


View more questions Search