    Questions about ABS sanitary tees and piping
    Are there any rules as to how far tees and other couplings and connections have to be from each other? I have a drain tee that is leaking and I need to replace it with a new tee. The problem is there is another tee right below it like 2" so if I cut the tee at the top and get a new tee to put in there I will only have 2" of pipe left to use to push into the new tee when I cement it together. Is it better just to remove both tees and separate them by like 6' it is ABS drain and vent piping. Thanks
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Oct 1, 2010, 04:14 PM

    Are there any rules as to how far tees and other couplings and connections have to be from each other?
    No!
    if I cut the tee at the top and get a new tee to put in there I will only have 2" of pipe left to use to push into the new tee when I cement it together. Is it better just to remove both tees and separate them by like 6' it is ABS drain and vent piping.
    If the tee in question is at the base of the run it would simply give the pipe more slope.
    If it wouldn't present a problem I can find no fault with close coupling the two tees, Just be sure slope is maintained. Good luck, Tom
    Milo Dolezal's Avatar
    Milo Dolezal Posts: 7,192, Reputation: 523
    Plumbing Expert
     
    #3

    Oct 1, 2010, 05:58 PM

    I agree with Tom. As long as you have enough pipe to glue new San T on, you are fine...

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Removing glued ABS fitting to ABS piping [ 5 Answers ]

I glued an ABS toilet flange to ab ABS pipe roughing. The fitting did not go down all the way and is 1/2" proud of the tile flooring. I now want to remove the fitting and replace with a new fitting. How do I do it without damaging the receiving pipe. Pipe is in concrete floor. Thanks, Bob

Abs piping keeps blowing out under air pressure [ 3 Answers ]

Abs piping on an air delivery system blows out under pressure. Does humity and heat weaken the joints?

Redesigning washroom, have some questions about the joists and piping [ 5 Answers ]

This is a second floor washroom, I am planning on doing some major home renos and would like my washroom to be redesigned, I want to move the toilet to another location, however to place it there the drain pipe has to cross the joists. How does one do that? Cut into the joists? Create a cavity...

PVC vs ABS piping [ 4 Answers ]

I am trying to change a room into a laundry room. I have run the copper piping for the supply lines. While demolishing the wall, trying to find where to connect the 2" pvc drain line, I came across 2" plastic tubing for the vent to the kitchen sink. The wall thickness is the same as the pvc ( about...

ABS vs PVC piping [ 4 Answers ]

Nb this sight has advised me not to use capital letters. Due to re-shingling I have had to take down my solar panels for heating the swimming pool along with all of the 1 1/2" dia. Piping, which is pvc. As it is over 20 years old and has been subject to ultraviolet rays I intend to replace it...


View more questions Search