Ask Experts Questions for FREE Help !
Ask
    mdemt's Avatar
    mdemt Posts: 1, Reputation: 1
    New Member
     
    #1

    Aug 25, 2010, 07:31 AM
    Have a switch that is piggybacked off another switch need 1st one hot always?
    I have a switch that is piggybacked off the switch that controls the light over my kitchen sink. I need the 1st switch to be hot all the time not only when the light over the sink is on. How can I fix this?
    hkstroud's Avatar
    hkstroud Posts: 11,929, Reputation: 899
    Home Improvement & Construction Expert
     
    #2

    Aug 25, 2010, 07:50 AM

    Not sure I understand your question. You have a switch that controls your kitchen light and want to do something but I don't know what. Tell us more about what you are trying to do.
    donf's Avatar
    donf Posts: 5,679, Reputation: 582
    Printers & Electronics Expert
     
    #3

    Aug 25, 2010, 11:38 AM

    Okay,

    If you have one feed, that is part of a switch loop, then you have a constant hot feeding both switches. Switches do not use a neutral conductor unless there is a pilot light or some other constant need.

    The constant feed, can feed two switches. Normally, feed from the ceiling is brought to the switches via the white conductor that has been re-tasked (marked with either black or non white, gray or green color to signify that it is a hot conductor).

    The way I would do it is to wire-nut two short black conductors to the white conductor (if it is the constant hot). One black pigtail would then feed the lower screw on each switch. That way, both switches stay hot and can be operated individually.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

1 hot to 2 hot - convert one switch to 2 switch to control fan and light. [ 4 Answers ]

Hi, I have a light fixure on the ceiling and want to replace that with a fan and light combo. I have a only one switch to control that but I want to replace that with 2 switches. I think I need to run another wire from switch to celing, is there another way this can be done?

Separate Fan light switch, fan switch and switch for can lights to one location [ 2 Answers ]

I have A circuit that has 6 can lights and a fan light. The power is at the switch box I need to know how to wire the separate switches for the cans,and the light on the fan, and fan (That would be in a three gang switch box.) to one location.

York residential furnace pressure switch problem code stuck switch [ 1 Answers ]

I have a york furnace P2MD12H06401A after 1 hour it shuts down and gives a 2 flash error for a stuck pressure switch. The switch is new can it be wired wrong? The old one had 2 white wires piggy back and 1 blue wire. The new switch has 3 separate terminals

Can Hot Water Heaters be PiggyBacked? [ 3 Answers ]

Just bought a twenty year old house in Loveland, CO. Has a two year old gas 50 gal. water heater in downstairs closet. Upstairs in master bath is a huge jacuzzi tub. Largest I've ever seen. Problem is the there isn't enough hot water in the heater to get the jacuzzi near full. Can another hot...

Connect a port on a remote switch to a secure segment on the local switch [ 4 Answers ]

I have 2 Netvanta 1224R switches. On the main switch I have 3 Vlans setup. Vlan1 = main network (example IP 123.231.5.1) Vlan2 = Web Access (Example IP 69.115.851.202) Vlan3 = Secure segment (Example IP 123.231.8.1) On the remote switch I have 1 Vlan. Vlan1 = Main network (example IP...