    Convection flow in recirculating hot water system
    I have a recirculating hot water system that is recirculating too fast and is losing a lot of heat. The pipes are in interior walls with pink insulation, but they are not directly insulated.

    The original installation had a pump that ran 24/7. I have turned the pump off and the system is still recirculating because of gravity convection.

    The furnace is a gas boiler with a computer in it. The unit has a connection for optimally controlling a recirculating pump. The pump is not currently connected to the boiler.

    The problem is that the system recirculates quite quickly even with the pump turned off. I think I need some kind of heat trap to stop the convection flow. But this trap needs to be strong enough to stop the flow in a recirculating loop. (I may have a trap already, but it isn't stopping the convective recirculation).

    Once the convection is stopped I can use the furnace controlled pump. The furnace control will run the pump about 3 min out of an hour and shuts it off over night. My goal is to get the system to completely shut off at night.

Check out some similar questions!

Recirculating hot water for a 1920 house [ 3 Answers ]

Is there a way to tap under the bathroom sink at the most distant hot water second floor (top) location. How do you do this? Does it waste a lot of hot water? Running the shower for 5 minutes also wastes a lot of water.

Failed hot water recirculating pump? [ 1 Answers ]

I recently had a new propane water heater installed. At the time of the installation, the plumber told me that the recirculating pump was not working and that this would cause my gas bill to be high. I still have hot water immediately at every faucet in the house, so I question if the pump is bad....

Two hot water heaters vs recirculating pump [ 3 Answers ]

I have a 2600 sq' house with 3 baths and nine people living in the home. I have a 50 gal hot water heater and need to decide to add another heater or a recirculating pump to boost my output. The home is all electric. What is the best way to go?

Hot Water recirculating pump [ 5 Answers ]

Howdy again, The hot water takes a long time to heat up due to the length of run from the water heater. So... Would installing a recirculating pump be a good idea? I have seen a type which connects the hot and cold and pushed the water from the hot side to the cold until it gets warm...

Hot water recirculating pumps do work, but [ 2 Answers ]

I can attest that the installation of a hot water recirculating pump (and sensor valve) does work. Hot water very quickly for the morning shower, really! However,. The 'however' is that I find that while the pump is on (in the AM for ~1-1.5 hr.), the hot water and cold water mixing in the...


View more questions Search
 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.