    Replace TRANE xe 1100 #TWN624c100A3 M225MH9CF condenser fan motor w/ generic mtr
    I am replacing a TRANE xe 1100 mdl#TWN624c100A3 serial M225MH9CFcondenser fan that is 20 yrs old it came wired with 4 wires the
    Red... hangs free unconnected
    Black
    Brown
    The new motor has 5 wires
    Red, black, white, brown, and brown tracer
    Black is no problem, the old motor purple went to red wire cliped into black box like connection board... old motor brown to ylw w/ brown tracer that goes to condenser
    What new motor wires go to the yellow w/brown tracer and what new wire motor goes to the red wire clipped into the black box panel. Thanks
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Jul 16, 2010, 03:14 PM
    Quote Originally Posted by peterpeters View Post
    I am replacing a TRANE xe 1100 mdl#TWN624c100A3 serial M225MH9CFcondenser fan that is 20 yrs old it came wired with 4 wires the
    red .....hangs free unconnected
    black
    brown
    the new motor has 5 wires
    red, black, white, brown, and brown tracer
    black is no problem, the old motor purple went to red wire cliped into black box like connection board... old motor brown to ylw w/ brown tracer that goes to condenser
    what new motor wires go to the yellow w/brown tracer and what new wire motor goes to the red wire clipped into the black box panel. Thanks

    Only follow the wiring diagram that is on the new motor or in the box it came in.

    Replace the old capacitor with a new one rated for use with the new motor.

    CAUTION Do not use the old capacitor.

    Tip: The two brown wires on the new motor go to the new capacitor.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Replace 1/4 hp condenser motor with multi hp AO Smith motor and Condenser [ 1 Answers ]

I am replacing my Payne 1/4 hp condenser motor with an A.O. Smith multi HP motor. I'm also replacing the capacitor (a round three prong piece) with an oval (two prong piece). In looking at the wiring diagram I'm supposed to connect the wires as follows: the two brown wires to the capacitor,...

Trane condenser fan motor to A.O.Smith condenser fan motor [ 2 Answers ]

The Condenser fan motor I removed from a Trane unit had four wires 1 black, 1red, 1brown and . The black wire went directly to #3 on the relay, the red wire went to the capacitor with black wire from #6 on the relay the brown wire went alone to the other side of the capacitor. I purchased...

Trane condenser fan motor TCH120C400AB [ 0 Answers ]

What is the rpm of Condenser fan motor of Trane Model # TCH120C400AB

Trane TR80 Condenser Fan motor overheating. [ 2 Answers ]

Hello all, I have a Trane TR80 system coupled with an XE 1000 A/C unit, and a few nights ago, I noticed that it was a little warm in the house when I got home from work. The fittings for the outside unit and the condenser coil had a fair amount of frost on them, so I shut the unit off to...

Trane A/C condenser motor not working [ 1 Answers ]

Is there a relay that triggers the Condenser motor? Also, I checked the voltage at the AC controller and it is at 26 VAC, is this a problem if it is intended to be 24?