    Compressor kicks in and back out
    I have a intertherm split unit that has always worked great,this morning I noticed it getting warm in the house,when I checked the outside unit the compressor wasn't kicked on,I turn the unit off for a few minutes and when I turned it back on the compressor buzzed for about 2 seconds and then kicked out,the fan still blows but the compressor isn't working,which way do I go now?
    Joshdta's Avatar
    Joshdta Posts: 2,549, Reputation: 45
    Ultra Member
     
    #2

    Jun 26, 2010, 06:18 PM

    Prob ally need a new start capacitor
    kf4ocj's Avatar
    kf4ocj Posts: 2, Reputation: 1
    New Member
     
    #3

    Jun 27, 2010, 05:34 AM
    Quote Originally Posted by kf4ocj View Post
    I have a intertherm split unit that has always worked great,this morning I noticed it getting warm in the house,when i checked the outside unit the compressor wasnt kicked on,I turn the unit off for a few minutes and when i turned it back on the compressor buzzed for about 2 seconds and then kicked out,the fan still blows but the compressor isnt working,which way do I go now?
    Thanks for your input,went outside this morning to check it closer,had a corroded wire on the start capacitor,fixed the connections and it started working,again thanks for all your input

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Fan on Outside Unit reverses direction when compressor kicks on [ 20 Answers ]

I have a Lennox 12ACB30-4P Value Series manufactured in 1996. It came with the house I bought 3 years ago. The unit never gave me any problem until 1 week ago when it would not cool. The fan would run, but the compressor would not kick in. There was a buzz every 20 seconds or so. A tech was...

Heat pump outdoor fan runs not compressor voltage at compressor good. New compressor [ 1 Answers ]

Have a new compressor. Just replaced fan runs compressor does not, have voltage at the compressor plug? What could stop from coming on high side and low side equal at 100psig.

Put new flywheel on now it won't start kicks back timming? [ 7 Answers ]

Have a crafsman riding mower 17hp I think had to put a flywheel on it now it kicks back and and shears off the flywheel key done it twice now?? Any help valves? This thing is only 2 years old not heavy use.? Help me thanks..

Compressor kicks on, but the blower doesn't [ 32 Answers ]

Hi, I have an outside compressor and a forced hot air furnace setup that's been working great for years... except today when I tried the A/C for the first time. Today, when I flipped the thermostat over to cool, I heard the compressor kick on, but then I noticed that the blower inside the...

Central A/C outside runs but compressor kicks on and off [ 2 Answers ]

Just cleaned the complete system, at furnace and outside. Had unit serviced (Sears Kenmore) for low freon, now when I turn on A/C the fan outside runs OK but the compressor kicks on then off after 10 seconds. This is the first time I ran the unit since it was serviced by a technician. Could this...


View more questions Search