    Revent
    I am moving a wall on my 2nd floor. The vent for my 1st floor sink and bathtub were running in that wall and tying into my main stack. I plan on running a separate vent up through my roof solely to vent those 2 fixtures. My question is can I leave the vent going vertically, 90 into the ceiling joist for 1 2 foot run, 90 again turning @ 3 feet towards the wall (now forming a 5-6 feet "L" shape) and 90 again up through the roof to vent. Could this potentially cause Vapor Lock?
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #2

    May 16, 2010, 01:22 PM

    90s in a vent aren't an issue but don't use them in wet apps. Can you post a picture or drawing? You plan sounds Ok but hard to picture in my mind.
    Ryankenney668's Avatar
    Ryankenney668 Posts: 2, Reputation: 1
    New Member
     
    #3

    May 16, 2010, 01:43 PM

    Sorry, new here. Not sure how to post pictures. Looking down from roof Pipe will come up (vertically), 90 right (horizontally say east), 90 left (horizontally say North) and 90 back up vertically out through roof.

    Thanks for the quick response :)
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #4

    May 16, 2010, 02:00 PM

    If this will be a dry vent you may use as many 90's as you wish just as long as you maintain 1/4 inch to the foot slope from the roof on back. Good luck, Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Revent or loop vent my kitchen island? [ 14 Answers ]

I am planning a kitchen remodel in which I will move the sink/dishwasher from the wall to an island about 10' from the current 2" stack in the wall. I also have a 2" iron stack running from my second floor showers through my kitchen to the basement (currently enclosed in a column that will run...

Revent 1st floor fixtures when adding attic 1/2 bath? [ 12 Answers ]

Hello, thanks ahead of time for any help you can offer. My house is a cape cod. I'm converting the attic into master suite with half bath. (yes, I had it checked, I have egress/access/structural support). My question deals with reventing. It is my understanding that all current vents have to be...


View more questions Search