    Neil23's Avatar
    Neil23 Posts: 2, Reputation: 1
    New Member
     
    #1

    Feb 25, 2008, 11:47 PM
    Replacement tub drain is in a different position
    Hi.

    I'm in the process of renovating my roughly 25 year old guest bathroom and have hit a snag that I'm hoping someone out there can help me with.

    My problem concerns the replacement tub I am trying to install. The existing drain is 15 1/2 inches off the back wall, but the drain hole on the new tub is 16 inches off the wall. I looked at altering the location of the drain, but it's a complicated arrangement of roughly 11 pieces of ABS without a place that I can cut it. To move it I would have to redo the whole thing plus open up the ceiling below which would be a huge deal, and even then it's not clear how easily I could make the change because it's not just boxed downstairs. I can provide more detail, but basically this option seems like a non-starter as it represents a huge amount of work and grief from the boss is almost guaranteed. :)

    Searches produced a series of postings suggesting notching the back wall and I was comfortable going that way until I realized that I can't notch into the back wall because it contains a 3 inch vent stack going up to the roof. At best I could notch the studs and move the tub back 1/8 to 1/4 of an inch, but not enough to line up with the existing drain.

    I'm wondering if I can install the waste and overflow at a slight angle and use the existing drain. It seems to me that it should work fine for the bathtub drain, but that the overflow might be a problem since it would no longer sit flush to the tub.

    If anyone has any suggestions I would greatly appreciate hearing them.

    Thanks very much for your help. I really appreciate it.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Feb 26, 2008, 06:16 AM
    Rather then change the trap for 1/2" why not pick up aq 1 1/2" flexible compression tailpiece,(see image) and cut back the trap raiser and connect with that.** or** you could fur out the wall 1/2". Your choice. Good luck, Tom
    Neil23's Avatar
    Neil23 Posts: 2, Reputation: 1
    New Member
     
    #3

    Apr 1, 2008, 09:05 AM
    Hi I just thought I'd post a follow-up in case others have the same problem in the future.

    The PVC part recommended would likely have been a good solution for me in many locations, but I'm located in Canada where ABS is used for waste and overflow.

    Fortunately one of the best plumbing supply stores in the city stocks OSB's waste and overflow kits in which the brass overflow pipe is corrugated to allow you to bend it to align with the existing drain. I would highly recommend this product as it worked extremely well and saved me from a huge problem. I used the 314Q kit, but there are a number available. I would encourage you to check out this excellent product on OSB's website at Welcome to Oakville Stamping & Bending Online.

    Neil
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #4

    Apr 1, 2008, 11:23 AM
    The PVC part recommended would likely have been a good solution for me in many locations, but I'm located in Canada where ABS is used for waste and overflow.
    I'm glad you're fixed up but I'm a little confused. Does replacing a faucet washer or a lavatory tail piece require you to pull a permit up in Canada? ABS and PVC can be used together with slip joint connections. What's the problem? Not going to pass inspection? On another note we stopped using ABS for drtainage back in the late 60's. PVC is more ridged and stands up better in the hot Florida sun. Haven't seen ABS out on the job for decades.
    Regards, Tom
    rotten_ronnie's Avatar
    rotten_ronnie Posts: 1, Reputation: 1
    New Member
     
    #5

    Apr 30, 2010, 01:09 AM
    Quote Originally Posted by speedball1 View Post
    I'm glad you're fixed up but I'm a little confused. Does replacing a faucet washer or a lavatory tail piece require you to pull a permit up in Canada?
    Nope; replacement is fine. Some municipalities require a permit for new plumbing installations, but unless you're gutting the place nobody will care much if you don't bother.


    Quote Originally Posted by speedball1 View Post
    ABS and PVC can be used together with slip joint connections. What's the problem? Not gonna pass inspection??
    Bingo, sort of. ABS is code in Canada.


    On another note we stopped using ABS for drtainage back in the late 60's. PVC is more ridged and stands up better in the hot Florida sun. Haven't seen ABS out on the job for decades.
    Regards, Tom[/QUOTE]

    There are two minor and one major difference between ABS and PVC. The minor differences: ABS is lighter, which may or may not be an issue, and ABS is more expensive, which might explain why PVC is favored in the US.

    However, there is a major difference; ABS has twice the thermal expansion ability of PVC. It's not such a big deal with relatively warm climates (say, no colder than -17C/0F) but where I live winter normal low is -40C/-40F.

    I've worked in remote areas (and I was in charge of water systems, so if it breaks, I'm the guy who has to fix it) in the north where February temps go down to -48C/-55F overnight. There's a whole host of issues that come up with temps like that, but pipe breakage is not one of them with ABS.

    Now, even though it gets cold in winter, my home town's normal summertime high is +40C/105F. ABS seems to perform just fine in the heat.

    I've never seen ABS fail in extreme cold, but PVC just shatters with the slightest impact at extreme cold temperatures.

    Horses for courses.

    -Regards
    hkstroud's Avatar
    hkstroud Posts: 11,929, Reputation: 899
    Home Improvement & Construction Expert
     
    #6

    Apr 30, 2010, 04:45 AM

    I'm confused. You said tub, Tom seems to be talking about a lavey drain. Glad you found solution but have a question. Do you have enough length in the tub shoe to cut and put in a short 22 1/2 ell. Same thing with overflow? Pipe sizes might not be the same as fittings however.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #7

    Apr 30, 2010, 07:04 AM

    Hey Herald ,
    Don't be confused. If you'll look at the date you'll see that the post about the lavatory was back in 08 while rotten ronnie posted today.
    Ronnie,
    Back in 60's we roughed with ABS.
    While it was just dandy in short drain arms when we rouged for a kitchen sink the heat from the sun would make the arm droop almost to the ground ands we had to brace our stacks to keep them from falling over. PVC, on the other hand held up real good under the sun.
    PVC may shatter behind intense cold, as you say, but down here we bundle up and turn the heat on at 65F. That's "intense cold" to us and PVC likes our climate just fine,
    Different strokes, etc! Regards. Tom
    hkstroud's Avatar
    hkstroud Posts: 11,929, Reputation: 899
    Home Improvement & Construction Expert
     
    #8

    Apr 30, 2010, 08:07 AM

    Sorry, guess I'm just getting old. Old, old and older.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Bath Tub Drain Replacement [ 3 Answers ]

I am replacing the bathtub drain in my daughter's house. The house was built in the mid-60's and has an enameled, cast iron tub. I have removed the old drain, but the replacement that I got at the home center doesn't fit. Specifically, the strainer basket on the replacement is too large to fit...

Tub drain in concert is too low for new spa tub [ 1 Answers ]

Greetings everyone, I am installing a whirlpool tub and it appears that the drain is about 1/2 inch too low. The drain is set in concrete. Is there any type of extension that can be put on the drain? Any suggestions? Thanks, Ed

Slow Tub Drain; Draining Sink Overflows Tub [ 8 Answers ]

Hello! I'm looking for advice about some bathroom plumbing issues. We live on the ground floor of a condo building that has a cement slab. The tub in our bathroom has an extremely slow drain (ankles submerged during a shower). We've tried to snake the tub drain both through the drain and by...

Bath tub triplever drain replacement [ 1 Answers ]

How can I remove an old waste plug from a bathtub triplever kit if the if the metal cross inside the old one is broke and the wrench made for it has nothing to grab onto?

Replacement tub drain [ 3 Answers ]

I am looking for a replacement tub waste plug. I was in the hardware store today and they had a wall full of replacement drain parts. The bathtub in my master bath has a drain that works fine but cosmetically was pretty beat up. It's 30 year old brass, and it was not going to clean up without being...


View more questions Search