    Have you ever heard of a bullnose
    In our master bath we have a sink, toilet and double sinks. We keep getting backup from the toilet and cannot use the sinks or tub as they will not drain. Does not show any slab leakage, but can't seem to know why the toilet backs up constantly, have had plumbers out 3 times and all they do is snake the toilet to unclog it, but it still returns. They say we have an illegal bullnose "t" connected in the slab that is probably blocks and can't snake it because it is a 90 degree angle not at a slant and we may have to completely jackhammer out all concrete to redo plumbing. Can you provide any insight or help and thanks. When you run a snake from the tub drain iit goes up the vent pipe, snake from sink it goes out the tub drain (weird).

    Kay Cox
    mygirlsdad77's Avatar
    mygirlsdad77 Posts: 5,713, Reputation: 339
    Plumbing Expert
     
    #2

    Apr 14, 2010, 03:14 PM

    I've posted a pic of a bull nose tee. Its basically a straight tee(non directional), and should never be used in drainage(especially under ground). The only real use for these in a drainage system would be as a cleanout when placed in the vertical.
    I would suggest having a see snake camera sent down the toilet drain to see what is under the floor. You may be able to just break up a small portion of the floor and fix the problem area. Hopefully there is only one of these in the system and you won't have to replace all pipes underground. Let us know how things go.
    Attached Images
     
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #3

    Apr 14, 2010, 04:55 PM

    Bull nosed tee, sometimes called a " Vent, Inspection or Clean Out Tee" has no curved throat to direct the flow. However even if the tee is bull nosed gravity alone should complete the drainage. Get a sewer cam down there and see where the clog is,
    Your plumbers don't what you have under the slab. Why don't they snake from a roof vent? Until you know what you have you can't make a repair . Good luck, Tom
    truck 41's Avatar
    truck 41 Posts: 221, Reputation: 21
    Full Member
     
    #4

    Apr 14, 2010, 09:27 PM

    If both sink and tubdrains are also affected by this then it may be more than a bullnose tee problem, and did this just start happening? How long have you lived in this home? Either way I third the advice to cam the line. Goodluck.---zeke---

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Is tile bullnose baseboard installed before or after floor tile? [ 8 Answers ]

My porcelain tile comes with a bullnose that I want to use as the baseboard. I found a response to another question, stating that the floor should be installed first, but I want a grout line between the floor tile and the baseboard, it would be very hard to make it uniform if the floor is...

Grainite Seams in Bullnose [ 1 Answers ]

I just had Granite kitchen countertops installed. Dark Beige and Black called Desert Armadillo. They have a black seam at the bullnose area where they connected with the top. Is this correct? I complained and the company stated it is that way.

Anyone heard of this? [ 24 Answers ]

Me and girl are young in college going out for not very long (less than a year) but we want to make it work even though she's leaving after a few months of the two of us and making the relationship ld... things good for a while talking once a week but then she dumps me kind of out the blue saying...

Has anyone heard ? [ 11 Answers ]

I just read a press release that they are taking the word gullable out of the dictionary.


View more questions Search