    PVC shower floor flange
    Hi,

    I will be installing a linear shower grate instead of a standard circular floor waste and had a question regarding the pvc shower floor flange, more specifically the adjustable drain barrel. Since the linear shower grate is 1" in height it seems I can just put the shower garte on top of the drain base and then mortar as I do not need a height adjustment, so can I get rid of the adjustable drain barrel and just install the shower grate on top of the drain base or is the drain barrel required by regulation?

    Please see link for linear shower grate pic and floor flange pic


    http://i692.photobucket.com/albums/vv284/malibu1101/capture.jpg

    Thanks
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Mar 18, 2010, 06:31 AM

    it seems I can just put the shower garte on top of the drain base and then mortar as I do not need a height adjustment,
    Please explain how the linear base will connect to the female threads in the flange type shower drain.
    Back to you,Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Connecting a PVC shower flange to cast iron [ 2 Answers ]

I need to connect my pvc shower drain to the cast iron, so I get my shower pan poured. This is a repair and there is old concrete for a base. There is an inch and a half around the cast iron about 7 inches deep. There is room to get a boot on to couple them, but there is absolutely no room to...

Replacing a PVC Toilet Floor Flange [ 1 Answers ]

My PVC Toilet flange is broken on a 3 inch PVC pipe on the 2ND floor. What type of repair Kit would I need to fix this problem without tearing up the bathroom floor and the kitchen soffet below to get to the pipe. I asuume, I would have to remove some more of the flange without cracking the pipe...

How to install a new drain/flange for a shower in a concrete basement floor [ 3 Answers ]

I have an unfinished basement that I am building a bathroom in. The floor in the basement is concrete, however the builder did install the PVC pipes in the cement floor so that the bathroom & plumbing is ready to be finishied. My question deals with how to install the shower draain so that it...

Running pvc for retrofit shower floor [ 22 Answers ]

I removed a one piece tub/shower enclosure and removed the old drain and overflow for the tub. I cannot get to the trap which is about 4" away from where the new drain will be. Can I use street 45's and angle my way to the top of the trap? I had a hard enough time cutting the pvc for the old drain...

Install PVC Adjustable/Flange Shower Drain [ 1 Answers ]

I'm re-doing my bathroom. Tile guys ripped up the previous composite/fiberglass shower pan which will be replaced with a tiled and mortared pan. I'm not doing the pan construction but do need to have an adjustable shower drain installed for the shower pan guy to work around. My current...