    Installing pex inside old galvanized
    I have a house that has 50 year old galvanized 3/4" pipe. It has started to give quite a bit of rust into my water, I am considering running 1/2" pex inside of the old galvanized so that it has protection from critters it any rats or squirrels find find their way into the attic and to also give the appearance of solid metal pipe with the convenience of a plastic liner.

    Has anyone tried this in the past, and if so other than the problems of having to unscrew all of the elbows to feed it through are there any reasons not to consider this combination?
    KISS's Avatar
    KISS Posts: 12,510, Reputation: 839
    Uber Member
     
    #2

    Feb 8, 2010, 12:41 AM

    The minimum bend radius is 6x the diameter, no won't work.

    http://www.zurn.com/operations/pexrh...sApplGuide.pdf
    OldTexan's Avatar
    OldTexan Posts: 2, Reputation: 1
    New Member
     
    #3

    Feb 8, 2010, 05:31 PM
    Thank You for the fast reply... That is exactly the type of information that I needed.

    It is too bad they do not make plastic lined pipe instead of it being galvanized, that would seem to be a logical solution since the main problems with steel pipe was the galvanization wearing away.

    Hmmm... maybe I have come up with a whole new market!
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #4

    Feb 8, 2010, 05:44 PM

    Besides the bend not working chances are pretty good your old 3/4 gal pipe won't allow a 1/2" PEX through due to the build up of rust, you may have pencil sized passages already

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Inside controls off.outside fan runs even when inside Heat is on [ 2 Answers ]

My outside unit's fan still runs even when inside controls are all set to off, or even when inside heat is being used.

Installing PEX Piping [ 1 Answers ]

I am replacing galvanized piping with PEX piping. I will only be replacing the piping in the basement and leaving the galvanized piping risers to the floors above. I will be using brass PEX fittings. Do I need a special fitting such as a dielectric union/coupling to connect from the brass PEX...

Pvc to galvanized [ 6 Answers ]

Can't seem to get a tight seal at the connection of the pvc fitting to metal. I sanded th piece of gal to try to eliminate some of the corrosion because I could not get to oring on the pipe. Should I use a sealer as well there were no directions with the pvc piece I bought. Thanks

Installing new toilet flange to 3" galvanized [ 3 Answers ]

I'm installing a new toilet in a basement and the plumbing was roughed in back in the early 40's. The problem I having is trying to find the right flange that will work with 3" galvanized pipe. From what I can see I don't believe it's cast iron, but it wouldn't suprise me if it is. I bought a 3"...

Copper to Galvanized [ 1 Answers ]

I need to replace some water pipes in my house to add Shut-offs and to remove some "hokey" setups.. my issue is that I have galvanized running up through the walls to the 2nd story bathroom. Everything else in the house is copper or PVC. I want to run copper to the galvanized, do I need Dielectric...


View more questions Search