    Sears Fifteen Horizontal Furnace
    Hello,
    I have a Sears Fifteen Horizontal furnace that will come on and then go out before the proper temperature is achieved. The fan will continue to run but the burner will not re-light until I reset it at the thermostat.

    Also, I had the blower motor replaced several years ago and the tech set it to run an extended period after either the heater or AC finished it's cycle. I would like to set this back to the normal run time. Any suggestions with either of these questions would be greatly appreciated. This is an electronic start unit and I believe it is 15-20 years old. Thanks again.
    NorthernHeat's Avatar
    NorthernHeat Posts: 1,455, Reputation: 132
    Ultra Member
     
    #2

    Dec 13, 2006, 05:54 AM
    First it wpo;d help to know who made that furnace for sears? There is a lot of ways furnace manufacturers adjust the time off fan, dip switch's, small jumpers etc. As for the burners cutting out that is usually a weak main limit or overheating caused by low airflow.
    DanaT's Avatar
    DanaT Posts: 2, Reputation: 1
    New Member
     
    #3

    Dec 13, 2006, 07:15 AM
    I knew that question was coming. I have looked all over this unit and I am unable to locate the manufacturer. However, I will look once again.

    I did remove the cover to the igniter and heat sensor, brushed them off with a paintbrush as well as tighten a loose ground connection and now the unit is coming up to temp properly.

    Again, I appreciate your assistance and will get back with the model/manufacturer when I locate it.
    NorthernHeat's Avatar
    NorthernHeat Posts: 1,455, Reputation: 132
    Ultra Member
     
    #4

    Dec 13, 2006, 03:12 PM
    Clean they flame sensor with steel wool,fine grut sand paper or crumpled aluminum foil, I don't think the paint brush is sufficient. Good Luck
    JonFurnace's Avatar
    JonFurnace Posts: 1, Reputation: 1
    New Member
     
    #5

    Feb 5, 2010, 02:01 PM
    I have a similar problem with a Sears Fifteen Natural gas electronic ignition furnace. When the thermostat calls for the furnace to come on, the burners come on at a low level and then almost immediately, I hear a "rattling" sound and the furnace shuts down. If nothing is done, the furnace never comes on again. However, if I shut the thermostat off and wait a couple of minutes, the furnace will light up again. Sometimes, this has to be done thrice to get the furnace to run. Then it usually functions OK for the rest of the day. I had this problem 10 years ago and cured it by sand blasting the igniter/sensor (looks sort of like a apark plug with three "prongs"). It worked flawlewssly until reccently and then statrted the problem again. This time I bead blasted it and it it notably better, but not 100%.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Older Sears Kennmore gas furnace [ 7 Answers ]

I have an older Sears Kennmore furnace, I'm guessing early 80's. Model # 867.763334 Furnace works great but intermittently does not work. When not working, only when I turn the power off and back on to the furnace will it work. Happens 3 times a week. Any ideas?

Horizontal Line in MS Word 2000 [ 13 Answers ]

How can I remove the Horizontal Line that goes completely across the page? How can I prevent it from happening again? I think there is something about holding down a key and pressing the "=" three times, but I cannot remember. Thanks.

Moving horizontal bands [ 2 Answers ]

I just replaced my front projection TV with a new rear projection HDTV. I had horizontal line/lines that moved up the picture in the old set and was hoping it would go away with the new set…no such luck. New set uses only the component inputs from my audio/video equipment that is located on...

Kitchen Sink with two horizontal drains [ 1 Answers ]

:confused: Bought a house recently. Kitchen sink a mess. I have never seen a kitchen sink with two drains; one per basket. Each basket has a tailpiece and P-trap that goes to the horizontal drain pipe. I hooked up my new sink the way the old one was and I am having a lot of trouble. I can...

Horizontal Wet Venting [ 5 Answers ]

I'm installing a master bathroom in a concrete slab. Unfortunately I've already poured the concrete. Along one wall from upstream to downstream I have a jetted tub, shower, and then the toilet. The sink is across from the shower. At the moment each fixture has its own vent. I'm trying to get...


View more questions Search