Ask Experts Questions for FREE Help !
Ask
    hedwards30's Avatar
    hedwards30 Posts: 1, Reputation: 1
    New Member
     
    #1

    Jan 7, 2010, 07:47 AM
    Kenmore power miser 70
    Our Kenmore Power Miser 70 main burner will not ignite. We cleaned the parts, we replaced the Gas valve and the coupler, and still no luck. Everything seems to be working. We get a flame, we get a clicking sound, and the fan will start to cycle the air, the only thing is the main burner does not ignite.
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Jan 7, 2010, 09:19 AM
    On most models you will check for 24 volts at the gas valve during operation. If no 24 volts you will have to trace the circuit back till you find the defective part.

    BUT if there is 24 volts at the gas valve and the gas valve does not open then the gas valve is usually toast.

    PS there is usually a knob or lever on the gas valve that has to be turned to on for the valve to activate. Many times a person will replace the thermocouple and get the pilot to work but they will forget to turn the valve to ON.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Kenmore Power Miser 6 40 Gal water heater (shorty) popping reset button [ 7 Answers ]

Hi, I have a rental property with the above described hot water heater and have had some trouble determining exactly what my problem is. Here is a breakdown of what I've experienced. Hot water line burst just above the top of the tank and ran for a period of days spewing hot and eventually cold...

Wiring a mister miser 6 kenmore hotwater heater [ 7 Answers ]

Hi We are having a heck of a time with wiring . The problem is this... Kenmore Mister Miser 6 30 gallon hot water heater... ok... the hot water heater has.. one blue wire, one black wire, and one yellow wire... our power supply has a black, red and black. We have no idea how we are suppose to...

Quiet miser [ 9 Answers ]

We have a blower problem it is a whirlpool quiet miser the blower was re wired but it stays running never cuts off... all the other controls work fine...

Water miser light flashes on my kenmore dishwasher [ 3 Answers ]

I bought a used Kenmore Dishwasher 665-16712000 9 months ago and it has worked great until now. The water miser light just keeps flashing and it won't start any cycle. If I hit the cancel/drain button the water miser light, the quick dry light, and the cancel/drain light all flash. Eventually...

Kenmore Miser 12 Electric 40 Gal H2O Heater [ 2 Answers ]

Let me get to my problem. I just installed a Kenmore Miser 12 Electric 40 Gal H2O Heater Model #153.321440. I have 120 coming from the breaker into each side of the thermostat (i.e. if I use my voltage meter and touch one lead to a ground and one to the black wire or red wire each gives me 120)...


View more questions Search