    PEX and Stubouts / Terminations
    I decided to use PEX in my renovation with a manifold/home run set up. Have already pulled all the tubing to each fixture, the manifolds have been mounted and connected, no leaks all is well. I'm undecided on how to handle the termination of each fixture tube. Under cabinets (kitchen island sink, bath vanities) I plan on using PEX to 3/8comp fixture shutoffs since the PEX will be hidden behind the cabinet doors. The toilet supply lines will come up through the floor. What do you suggest I do to pretty that up a little? I'd rather not have the blue pex tube sticking up through the floor, but I don't know if I want to use a PEX to copper stub. Should I switch to copper under the floor or go with one of those finishing sleeves that slide over the PEX for these cases?
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Nov 28, 2006, 06:17 PM
    If you could come up in the wall and install a pex X 1/2" dropeared Ell,(see image) you could exit with a chrome 1/2" nipple past 1 chrome face plate into a threaded chrome angle stop and sullpy the toilet in the usual way. As it is your best bet would be to sleeve the pex up to a inline pex valve and convert to 1/4" chrome tubing. Good luck, Tom
    BigRed1500's Avatar
    BigRed1500 Posts: 70, Reputation: 8
    Junior Member
     
    #3

    Nov 29, 2006, 10:40 AM
    Of course, the drop ears. Don't know why I didn't think of that. I have a bunch of them for the showers/tub spouts, I can do the same thing here. Thanks for the tip!

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Pex Plumbing [ 5 Answers ]

I'm hoping some one can help with my question regarding Pex plumbing (AKA Zurn Pex). I have recently run Zurn Pex throughout my renovated home for use in baseboard heating. The pex is used for supply and return and traditional copper baseboard will be installed as the heating element. The plan...

Water pressure using PEX manifold [ 3 Answers ]

I am getting ready to re-plumb my entire house. I plan to switch from Copper to PEX. The reason is that I have a well and the water causes pinhole leaks in the copper. My question is: The current setup is a standard tee and branch. I have 1/2" pipe coming off of the 3/4" mains in the...

PEX supply lines - keep from freezing [ 6 Answers ]

I am adding a 1/2 bath to the upstairs of our 170 year old cape and am considering the best route to run my PEX supply lines. Because there have been several additions and alterations to the house over the years, there are oddities in the structure that make it difficult to describe my situation...

Sizing guide for pex supplies [ 5 Answers ]

hello again speedball, so I've decided to tackle my pex plumbing project myself and not shell out $700 to the "I know a guy" guy. From what I've read so far, sizing pex is the same as copper, but I value your input greatly. I am running supplies for an attic half bath. The total run for...


View more questions Search