Ask Experts Questions for FREE Help !
Ask
    woodisgood's Avatar
    woodisgood Posts: 1, Reputation: 1
    New Member
     
    #1

    Dec 17, 2009, 05:12 PM
    Symmons model A
    I have an older Model A shower valve. Was working fine. Got cold last night and now will not flow any water even in full on(hot ) position.No, it is not frozen. BUT,, when I open the lav faucett next to the tub the water flows full cold from the open shower valve.. Are these also sensitive to pressure? I have 4 other shower valves in the house and they are OK. Dirt? Limit stop? This happened overnight . Not gradually...
    EPMiller's Avatar
    EPMiller Posts: 624, Reputation: 37
    Senior Member
     
    #2

    Dec 18, 2009, 07:24 PM

    I have only worked on one flavor of Symmons shower valves, but it sounds like a stuck hot water regulator in the valve. They are supposed to maintain the outlet temperature even if the hot input temp varies a bit, and if the regulator gets stuck things don't work. Also I think these won't flow anything if the cold line doesn't have pressure. Check that too. If that is OK then rebuild the valve and things should be back to normal.

    They are fiddly to work on, and you have to replace several pieces to rebuild them. Don't skimp and only replace the one seal. Use the whole kit even though it is expensive. I don't like them, but the other options for a temperature controlled valve are not cheap either, just easier to work on.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Symmons - Temptrol Diverter [ 22 Answers ]

I have the above diverter in my bathroom. Recently it started to leak from the diverter handle that changes the use from tub to shower. I purchased the Symmons TA-25A Iverter Spindle to replace old. My problem is that I do not know how to remove the old spindle. Can anyone help me with my problem?

How to disassymble my symmons shower value [ 0 Answers ]

Is there a diagram of how to disassymble my symmons shower value. There is limited hot water. I suspect that the value inside needs to be soaked in vinegar.

Symmons '76 Temptrol Model A [ 19 Answers ]

Hello, I purchased a TA-10 to replace the spindle in my Symmons '76 Temptrol Model A. After removing the original spindle I notice that the replacement part is different. Namely, there is no thread on the largest circumference part on the replacement part whereas the original has a thread....

How to replace symmons spindle [ 1 Answers ]

How do you remove old symmons spinde and replace it with a new spindle and diverter Handle??

Symmons temptrol - no water [ 2 Answers ]

I'm getting nothing but a dribble on hot and cold, tub or shower settings. Was fine until today. Any way to tell if it is the valve or seat? There's nothing else to replace, right? Thanks


View more questions Search