Ask Experts Questions for FREE Help !
Ask
    Montrose's Avatar
    Montrose Posts: 1, Reputation: 1
    New Member
     
    #1

    Dec 8, 2009, 12:24 PM
    Horizontal toilet stack
    I have a toilet drain in a straight line from the toilet to the basement (length about six feet). The stack is close to the toilet, and the sink drains into the stack. I would like to relocated the stack about 15 inches, to move it into a wall. This would require a short horizontal run for the stack from the toilet drain to the new location of the vertical stack. The sink would still drain into the stack.

    Can there be a short run of horizontal pipe as part of a toilet vent/stack system?

    Thanks
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #2

    Dec 8, 2009, 01:55 PM

    So will the sink still be draining into this stack, if so no horizontal run but a slope of 1/4"/f must be maintained.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #3

    Dec 8, 2009, 06:33 PM

    I'm a littoral guy so when you say
    I have a toilet drain in a straight line from the toilet to the basement (length about six feet).
    you're telling me that your toilet doesn't connect to the stack but drops directly into the basement? And that the basement's only 6 feet under the toilet?
    If you're asking if your toilet can move next to the stack and still be vented the answer is yes. Is your first statement correct or did I misunderstand it? Cheers, Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Can a new shower use the toilet stack to drain? [ 1 Answers ]

Hello! Your website is wonderful... it makes me believe that you may have the answer to a question that six plumbers in Los Angeles couldn't. I have a guest bath in my condo that I would like to install a shower in. My hot water heater is located in the bathroom, in a 3 x 3.5 foot closet. ...

Toilet to vent stack distance? [ 4 Answers ]

Hi. I am renovating the 2nd floor bath. Everything worked fine before the reno. I am planning to move the vent stack about 14" further from the toilet than it is now. (the horizontal waste run continues past this vertical vent stack and then goes down vertical into the basement). The sink and...

Venting of a toilet 3 inch horizontal drain line [ 1 Answers ]

How far away from a vent can a toilet be installed 3 inch horizontal pipe >Moved from Forum Help<

Basement toilet vent stack [ 1 Answers ]

I am putting a toilet, shower and sink in my basement, on an outside wall. We are on a septic system and I am chosing to use a collection tank and ejector sewage pump. How do I vent this system? Can I just go out through the joist headers? There is no stack remotely close that goes to the roof that...

Moving toilet stack under concrete [ 1 Answers ]

We have already cracked our concrete and now have access to the toilet stack to re-route to the location we want. The issue is the sewer pipe is covered with ground water. We've tried draining the water but it keeps coming back. This isn't surprising given the grade of our house. We're wondering...


View more questions Search