    Trane XV90 furnace won't heat
    Inside temp is 48 degrees, hard to type.. turned power off and waited and then turned back on with Trane VX90 furnace only 2 years old. Blower works but only cold air. Green light came on, it sounded like it was trying to work, then red light blinks three times (the portal glass you look through).. any suggestions? I would LOVE HEAT tonight and not have to call repair tomorrow..
    Thanks a lot
    TxGreaseMonkey's Avatar
    TxGreaseMonkey Posts: 16,761, Reputation: 5597
    Uber Member
     
    #2

    Dec 8, 2009, 12:56 AM

    Check the hot surface ignitor. If it doesn't glow, current won't flow to the gas valve. The ignitor and gas valve are connected in series. They are easy to replace, just make sure to turn the power to the furnace off first and don't touch the grey surface of the new ignitor upon installation. Replacement ignitors generally go for around $25.50, including shipping, on eBay.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Error Codes Trane XV90 [ 3 Answers ]

.House took too long to heat from 60F to 68F. My Trane XV90's error code light blinks constanlty red. Do I have a problem?

Trane xv90 troubleshoot [ 1 Answers ]

Can you tell me if I can reliably replace the existing but faulty CNT 03777 integrated furnace control with the next version (CNT 04985), or should I spend twice as much on the current version (CNT 05160)? Thanks

Trane xv90 leaking [ 1 Answers ]

I have a 2 year old Trane XV90 furnace. Here is my problem: Yesterday the AC was on while we were at work. The AC unit appears to be working fine but what I noticed is there was no air movement out of the ducts. I went down to check on the furnace blower only to find a puddle of water under my...

TRANE XV90 error code? [ 4 Answers ]

The owners manual does not have a list of error codes for reference. The unit does not actually display a code (no pause), the light consistently blinks. I have never noticed this before, is this normal or something that should be looked into. Thanks!

Trane XV90 fan speed [ 2 Answers ]

Hi. I have a Trane XV90. I keep the fan running all the time, as was recommended with the DC variable speed motor in this model. When not in heating or cooling mode, the fan runs at 30% to keep the system pressurized and the air moving. My question is, does anyone know how to kick the fan speed...