    Vent shower floor drain
    I am remodelling a shower in my basement. The showr currently has a 2" galvanized vent that emerges from the slab and ties in to the vent stack for upstairs bathrooms. This existing shower vent is about 18 inches downstream of the shower drain, and 18 inches further downstream the drain line it enters the 4" sewer line right at the main vent stack for all three toilets in the house. My question is, do I need this shower vent, or will the toilet vent stack 3 ft away be sufficient? The existing 2" pipe comers right up through where I want to put in the new shower, and is rusted to boot.
    cyberheater's Avatar
    cyberheater Posts: 321, Reputation: 12
    Full Member
     
    #2

    Dec 5, 2009, 08:02 AM

    There are good plumbers on here.

    It would help to show a diagram or pic.

    Depending on code and a host of other reasons, getting rid of a vent is not really a good idea, unless you can somehow ensure it is adequately vented in another way. You should not count on the 4" stack for your venting because in this case, because it sounds as though you would have one or more other appliances draining into it from above - then it cannot be used as a vent. Wet venting is possible, but that has considerations applied to it.

    Post a pic, or a diagram so that the pro's here can help better.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #3

    Dec 5, 2009, 09:17 AM

    What area do you live in? Do you know what plumbing code you fall under? Perhaps in your area a shower vent's mndatory. In the meantime most basement bathroom baths go down like this. Toilet connects to sewer main or the stack vent. Lavatory connects to toilet drain and runs a vent off the top the stubout tee out the roof or revents back into a dry vent in the attic.. The toilet wet vents through the lavatory vent and the tub/shower connects to the lavatory drain and is wet vented by it. This is a normal rough in and is acceptable both by local and state codes and also The Standard Plumbing Code Book in 90 percent of the country. Check your local codes to make sure you're not in the excluded 10 percent.. The vent off the lavatory may be run out the roof or revented back into a dry vent in the attic. Good luck and thank you for rating my answer. Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Install second floor bathroom drain and vent [ 18 Answers ]

Hello, I am taking on the challenge of installing a toilet and sink on the second level of my house and wanted to confirm the best options for sewage lines. It's an older house and I'll be causing quite a bit of damage to existing walls/floors so want the best solution before I go ahead with...

Are vent pipes needed on laundry sink and floor drain in basement [ 5 Answers ]

I have a room that is on the back of my house at the same level as my walkout basement. I currently have only a French drain in the center of the room. I would like to put in a laundry sink and a proper floor drain in that room. The room has a concrete floor and the main 4" drain line from the...

Vent for a 4" floor drain [ 1 Answers ]

What size is the vent ona four inch floor drain?

Drain vent and tie in for new second floor laundry [ 6 Answers ]

I'm adding a second floor laundry in an unused closet. The space has an interior wall with an unused return air duct that goes straight down to the unfinished basement right next to the main house drains. Lucky, I know.. There are two places I can tap into the drain at the bottom of the duct....

Converting cast iron floor drain to shower drain [ 3 Answers ]

I am adding a bathroom to my basement, which has partial (complete? ) plumbing already roughed into the floor (in 1976). Sewage lift station (vented) is 3 ft from 4" styrofoam plug (toilet), 4 ft from 1 1/2 inch cast male pipe end extending through floor (lav, have already added vertical vent...


View more questions Search