    Hard wire focus Pro 6000 thermostat
    I just installed a Honeywell focus pro 6000 programmable thermostat I have a boiler with a indirect hotwater tank and a taco sr502 switching relay.. On thermostat I wire red to r white to w and blue to c. On switching relay I wire white to on left termial and red to right termial which I had the old one working on also hooke up the blue to the common side of the 24 volt on the taco 502 . Problem is I still need the batteries installed if I take the batteries out it doesn't light up . Does this thermostat require the batteries to be in place? It says either or in manual.. thanks for any help it is a heat only system now..
    Guysr1
    guysr1's Avatar
    guysr1 Posts: 2, Reputation: 1
    New Member
     
    #2

    Oct 16, 2009, 04:22 PM

    I solved it myself all I had to do was switch the red and white from thermostat to where the white was on taco zone 1 tt left side was white right side was red . Now left termial is red and right terminal is white simple but frustrating to figure out
    Now don't need batteries.. can use for backup still.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Vulcan CX90 and Honeywell Focus Pro 6000 [ 2 Answers ]

Hi, I'm trying to install a Honeywell Focus Pro 6000 controller to a Vulcan CX90 Ducted Heating Unit. There are 6 wires coming from the CX90 marked A,B,C,D,E & F. The wiring diagram for the CX90 is no help because all 6 wires disappear into a decoder unit. Can anyone offer any help on wiring...

Connection of are RC Rh wires on focus pro thermostat [ 1 Answers ]

I have a lennox heat pump (x 15) air handler (CBX 32MV) and a new honeywell thermostat (focus pro) wireless thermostat. The Equipment Interface Module (EIM) has R, Rc and Rh connections all factory jumped together. The installation manual says to remove the RC - Rh jumper if the system has two...

Wiring a Honeywell Focus Pro 6000 [ 1 Answers ]

I have a Carrier Heat Pump (about 5 years old) that had a non-programmable White Rodgers thermostat 1F59-11. The configuration of wires for the old thermostat are as follows: C = blue wire G= green wire R = red wire O = orange wire W= white wire Y = yellow wire L = empty B = empty

Hard wire speaker wire to after market radio [ 2 Answers ]

My radio in my honda accord will not kick out sound. The power works, but I think the speaker wire is not connected it is a after market pioneer radio and I don't know what wire to connect from the radio to the factory wire.

Hard wire 3 wire to 4 wire 220 service [ 2 Answers ]

How do I hard wire my 3 wire (red,blk & bare copper wires) 220vac cooktop to the 4 wire (black/white stripe,black/red stripe, blk/blk & bare alum wires) in the house supply j-box ?


View more questions Search