Ask Experts Questions for FREE Help !
Ask
    dhloescher's Avatar
    dhloescher Posts: 5, Reputation: 1
    New Member
     
    #1

    Oct 13, 2009, 06:48 PM
    Pedistal sink installation
    My water lines and drainage is down threw the floor. How do I install a pedistal sink getting at least the drain line within the pedistal.
    Milo Dolezal's Avatar
    Milo Dolezal Posts: 7,192, Reputation: 523
    Plumbing Expert
     
    #2

    Oct 13, 2009, 07:17 PM

    Is your drain coming from the wall ? Are you on concrete slab or raised foundation ? Please, answer these two questions first... Also, you could post a photo of the sink area. Thanks..
    dhloescher's Avatar
    dhloescher Posts: 5, Reputation: 1
    New Member
     
    #3

    Oct 14, 2009, 03:22 AM
    Quote Originally Posted by Milo Dolezal View Post
    Is your drain coming from the wall ? Are you on concrete slab or raised foundation ? Please, answer these two questions first...Also, you could post a photo of the sink area. Thanks..
    The drain and water lines come up through the floor. The area has a crawl space under the floor. I thought of moving the drain to behind the wall so I would be coming out of the wall instead of through the floor but that would be too much of a problem. The house is 120 yers old. Thanks.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #4

    Oct 14, 2009, 05:00 AM
    That "S" trap drain line can turn into a real problem if it comes up through the floor anywhere near the china base. Check to be sure you have the room to install your lavatory.
    The supplies can be picked up with two chrome 1/4" tubes and chrome inline angle stops. Good luck, Tom
    Milo Dolezal's Avatar
    Milo Dolezal Posts: 7,192, Reputation: 523
    Plumbing Expert
     
    #5

    Oct 14, 2009, 09:47 AM

    Put that trap below the floor... First I would dry fit it: place ped-lav exactly where I plan to install it. Then mark the outline of the leg on the floor. Then, drill hole right next to and behind the leg. You can do the same with the water lines. Once under the house, you can connect it as pictured.
    Attached Images
     
    dhloescher's Avatar
    dhloescher Posts: 5, Reputation: 1
    New Member
     
    #6

    Oct 14, 2009, 11:08 AM
    Quote Originally Posted by Milo Dolezal View Post
    Put that trap below the floor..... First I would dry fit it: place ped-lav exactly where I plan to install it. Then mark the outline of the leg on the floor. Then, drill hole right next to and behind the leg. You can do the same with the water lines. Once under the house, you can connect it as pictured.
    That sounds like a viable solution. I'll have to crawl under the house and see what I have for space. You would not believe the mess down there. I have wires and pipes running all over the place. Hard to tell what is what. Will get back and let you know if I was able to move. Thanks a bunch. Dl
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #7

    Oct 15, 2009, 12:44 PM
    Put that trap below the floor
    Milo came up with a workable solution. Put the trap in the crawl space. This makes the installation "doable". Nice thinking outside the box, Nilo.. Give yourself a pat on the back and two weeks vacation in Aruba. Regards, Tom
    dhloescher's Avatar
    dhloescher Posts: 5, Reputation: 1
    New Member
     
    #8

    Oct 18, 2009, 03:41 AM
    Quote Originally Posted by speedball1 View Post
    Milo came up with a workable solution. Put the trap in the crawl space. This makes the installation "doable". Nice thinking outside the box, Nilo.. Give yourself a pat on the back and two weeks vacation in Aruba. Regards, Tom
    I want to thank all you guys out there. Your answers were helpful. As it turns out, I should have listened to my son who kept telling me I had the base upside down. When it finally sunk in and I turned the base around, that put the opening in the back at the top and I had access to connect the drain pipe. It was still tight but workable. Again, thanks for the help. Dl
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #9

    Oct 18, 2009, 04:38 AM
    Thanks for the update. Let us know how it's working. Good luck, Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Sink Vanity Installation [ 4 Answers ]

Hello, my husband and I just purchased a brand new sink vanity for our powder room. We removed the wall mounted pedestal with no problem and then realized that the piping coming from the wall is wider then the opening for the vanity. Is there any way to resolve this short of cutting into the...

Utility Sink Installation [ 2 Answers ]

We are installing a utility sink and are not sure of the standard installation heaight for a utility sink. Do you know the height and where I can find that ifo on the net?tttt

Utility Sink Installation [ 1 Answers ]

I would like to install a utility sink in my laundry room. Currently, my washer drains into a standpipe, and I would like the sink to be a simple drainage station with no faucet, with the washer draining into the sink. I will call the local plumber for this project. My first question is, what...

New Kitchen sink installation [ 1 Answers ]

I have just installed a new stainless steel kitchen sink, and I am having a problem with the two front corners being raised. The clamps that came with the sink do not hook into the corners which is where I need them the most. How can I get the two front edges to lay down?

Two speed pedistal fan switch [ 4 Answers ]

Let neighbor borrow fan during hurricane Rita. It is 2 spd.30in pedistal fan. Returned with pull chain switch missing.Old switch positions were1 off, first pull low, second pull off, third pull high,pull again, off.have no idea how switch was wired. Tried ceiling fan switch in various wiring combos...


View more questions Search