    Leaky copper joint fitting
    I am not a plumber, but I soldered a T-tting into a ½" copper pipe, using a propane torch. I used flux (which was 10 years old, does it expire?) but unfortunately, it has a slight leak because apparently not enough solder got into one of the joints. Then I tried to touch up by adding more solder, but it ended up just getting a glob of solder on top without fixing the leak. Is there a way for me to get the solder in there to stop the leak, without replacing the T-fitting?
    KISS's Avatar
    KISS Posts: 12,510, Reputation: 839
    Uber Member
     
    #2

    Aug 7, 2009, 09:14 AM

    Sometimes it works. Sometimes it doesn't and you have to replace the fitting.

    Did you prep it properly by sanding or using the tool for the connected pieces?

    If your uncomfortable soldering or if this is now a repair, you can pre-tin both pieces and wipe with a damp cloth and pre fit.

    In general, your heating one side of the fitting and applying solder to the other side.

    Sometimes the issue is water.

    Also make sure there is an opening in the system while soldering.

    At this point, you may be able to reuse the fitting.
    afaroo's Avatar
    afaroo Posts: 4,006, Reputation: 251
    Ultra Member
     
    #3

    Aug 7, 2009, 10:51 AM

    KeepItSimpleStupid have stated very well follow his instruction for more info please open the link below and will show you step by step how to solder, good luck.

    John

    Working with Copper Pipe | DoItYourself.com
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #4

    Aug 7, 2009, 11:21 AM
    Quote Originally Posted by redss View Post
    I am not a plumber, but I soldered a T-tting into a ½" copper pipe, using a propane torch. I used flux (which was 10 years old, does it expire?) but unfortunately, it has a slight leak because apparently not enough solder got into one of the joints. Then I tried to touch up by adding more solder, but it ended up just getting a glob of solder on top without fixing the leak. Is there a way for me to get the solder in there to stop the leak, without replacing the T-fitting?
    Shut the water off and blow the line clear with a compressor or air bottle. Leave the line open for steam to escape and commence to heat the tee and boil the moisture out. When the solder begins to run swab the joint with flux and run the tip of your solder around the joint while applying more heat. When the solder gets sucked in the joint you have a good solder joint. Good luck, Tom
    Milo Dolezal's Avatar
    Milo Dolezal Posts: 7,192, Reputation: 523
    Plumbing Expert
     
    #5

    Aug 7, 2009, 07:15 PM

    As said above: NO WATER in the pipe is the key word. Then, make sure you heat the fitting up well. Sometimes you can touch it up w/o taking the joint apart - but as I learned long time ago - it is the fastest fix if you just take it apart, clean again, re-apply flux and resolder.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #6

    Aug 8, 2009, 07:32 AM
    Milo,
    the fastest fix if you just take it apart, clean again
    That's what you and I would do. However for the asker this will give him 4 joints to clean,flux, and solder. My way would not have him cut the pipe and add a coupling.

    While that might not be the easiest or fastest but it's for certain the simplest. Regards, Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Best way to cap a copper water line: compression fitting or copper cap? [ 29 Answers ]

Hi all, Unsuccessfully tried to cap a copper water line by soldering a pre-soldered cap onto the end. Took all the proper steps, cleaned the ends of the pipe and fitting first, then applied flux around both. Wasn't quite sure what I should be heating, so I just heated everything. After my first...

Tips on copper compression fitting? [ 11 Answers ]

My problem is whenever I work with coppoer compression fittings, I never seem to get a good seal and something always leaks. Are there any tips on how to do it right? Should I use a hack saw verse my Reciprocating Saw to cut the tube? (SLow vs Fast). I know the cut has to be straight, then...

Reorienting a copper fitting [ 14 Answers ]

I have 3/4" copper water supply line that enters my house through the basement wall, makes a 90-degree turn and runs for a short distance horizontally, makes another 90 and goes vertical for a short distance, then through another 90 to horizontal where it goes through a pressure reducing regulator...

Copper Pipe Compression Fitting [ 7 Answers ]

I'm installing a dishwasher, I've never had one before so I am making all new pipe connections. I'm trying to add a t-fitting and then a valve to a copper water line to be able to turn off the dishwasher water supply while still being able to use the sink. I was told a T-compression would work. ...

Connecting PVC to Threaded Copper fitting [ 2 Answers ]

I have a fitting in a wall which began leaking with mold developing on the wall board. When I took out the wall the culprit was a fitting between a female threaded copper fitting and a male PVC fitting in a hot water line. I initially took out the PVC fitting and fitted the joint with a new fitting...


View more questions Search