    Sump Pump noise
    Hi,

    I just had a new sump pump installed about 2 weeks ago. It works well but when it empties there is a loud rattling noise that follows. My assumption is that it is shaking the sewer pipe as the water is being forced out of the house and when the unit shuts off it creates a vacuum that can't properly release pressure so it shakes the pipes.

    Does that sound right? I have looked at a few different air break valves (including Studore) but before I purchase one I want a second opinion as to what might be causing this noise. Also, I am a layman at plumbing but I have been able to tackle most plumbing issues that we've had in the past. I think installing an air break valve sounds pretty straight forward and am hoping to do the work myself.

    My last concern is that I have read about a 1/8" hole that is supposed to be drilled in the pipe just above the pump. My pump is submerged and the pit is pretty deep so I can't tell if I have this or not, is it critical to the issue that I have this hole?

    Thanks, Elizabeth in PA
    hkstroud's Avatar
    hkstroud Posts: 11,929, Reputation: 899
    Home Improvement & Construction Expert
     
    #2

    Jul 13, 2009, 09:28 PM

    The rattling is probably the water in the pipe flowing back down into the sump crock. Sometimes, depending on how high the pipe is, that is enough water to make the pump come on again. In that situation you have to put a check valve in. If the pump pipe is where it can freeze you drill the hole in the pipe to let the water below the check valve out to prevent it from freezing. Check valve should be at an elevation higher than the end of the pipe, that way water in the pipe above the check valve will syphon out.
    Liz Schindler's Avatar
    Liz Schindler Posts: 4, Reputation: 1
    New Member
     
    #3

    Jul 14, 2009, 07:57 PM

    Hi Harold,

    Thanks for reply. I don't think it's water running back to the pit because the water level doesn't rise once the pump kicks off. It's just a really loud shut off noise. The pipe from the pit to the ceiling is about a 15' run then a 90 degree turn to the left and a 20' run to the sewer line. Do you think I should put in the AAV?

    Thanks, Elizabeth
    KISS's Avatar
    KISS Posts: 12,510, Reputation: 839
    Uber Member
     
    #4

    Jul 14, 2009, 08:41 PM

    I think it's in effect "water hammer". In esscense, when the pump shuts off, the pipes shake and make a lot of noise.

    If this is true, then:

    A vibration isolator. I used a short piece of corrogated radiator hose in the section of pipe near the pump.

    The rest of the pipe should be resonably secure.

    Not all pumps require the weep hole, nor are check valves required for all pumps.

    You failed to mention how far up the pump has to pump.

    Sump pumps should not drain into the sewer.

    Is this a sewage ejector pump?

    If so, a flex coupling is still required, but a radiator hose won't do.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #5

    Jul 15, 2009, 05:28 AM
    You should have a check valve installed near the pump. Do you have one? Regards, tom
    Liz Schindler's Avatar
    Liz Schindler Posts: 4, Reputation: 1
    New Member
     
    #6

    Jul 15, 2009, 08:31 AM

    I did mention the run of my pipe from the pit to the 90 turn as 15'. That's how far it has to pump up before going horizontal and into the waste water line.

    Speedball, you would recommend a check valve as opposed to an AAV? How do they compare?

    Thanks for all the help.

    Elizabeth in PA
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #7

    Jul 15, 2009, 09:12 AM

    No AAV needed but yes on the check valve. I think the weight of the water suddenly stopping causes a water hammer like effect as point out by KISS.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Sump pump [ 2 Answers ]

I would like to say thank you in advance. THis is the first time I have ever dealt with a sump pump. My sump pump in the basement has gone out. I have tried draining the water; however the water level remains at the same spot. Am I just being impatient or am I doing something wrong?

Sump pump with a banging noise [ 2 Answers ]

We have lived in our newly built home for three years now. Recently we have had huge amounts of rain and snow. You can just hear the water rushing through our sump pump however it has made a banging noise like the sound of closing a door very gently. It has slowed as the ground is a little...

Sump pump necessary? [ 1 Answers ]

I just moved into a 20 yr old home about 2 months ago. The house is built on top of a hill and it has a walkout basement below grade. The basement is finished except for one room that is the size of a one car garage, and this specific area of interest is below that garage. The walls are cinder...

Sump pump [ 2 Answers ]

When it rains my sump pump works ,but there is a bab smell??


View more questions Search