    Well priming
    Hi,
    All of a sudden I had no water. I went down stairs and found the pressure gauge and turned the lever up to get a spark and lowered it until pressure stated to build up and water was coming back into the system. The problem is the gauge rises as high as 60 and clicks off down to 40 and back up to 60 and eventually within hours drops back to 0 again with no water and I have to do this over again. The water I do get is not with a lot of pressure. What is my next step?
    Bob
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Jul 1, 2009, 07:26 AM
    I would give a good hard look bat the check/foot valve. If it's not closing then your system would drain back into the well. Good luck, Tom
    jlisenbe's Avatar
    jlisenbe Posts: 5,020, Reputation: 157
    Uber Member
     
    #3

    Jul 1, 2009, 01:11 PM

    Your post is a little confusing since you label the post "well priming" but don't refer to priming the pump. SB answered you accurately if we assume your pump is above ground, which the priming reference would seem to indicate. Your pressure should hold at 60# when the pump cuts off and no water is being used. If it slowly drops (and you can verify that by simply watching the pressure gauge for several minutes), then it would indicate a faulty check/foot valve or possibly a leak somewhere "upstream" between the tank and the house. One way or the other, once your pressure drops 10# below the cut off point of 40#, the switch is shutting off and you must reset it. Perhaps that is what you meant when referred to "priming".

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Priming jet pump [ 1 Answers ]

I am replacing a water tank and I need to reprime the pump. How is this accomplished?

Pump priming [ 1 Answers ]

Today I tried to have my house power washed and within less than half an hour my water pump was drained with no pressure reading on the gauge. AS I have done before, when pressure goes below about 20 lbs, I shut of pump. After it stands for a few hours it will usually begin to pump and fill my...

Priming the pump [ 1 Answers ]

My parents are out of town and when I came to check on the house I went to the restroom and flushed, it wouldn't no water was in the tank, I have heard my dad talk about sometimes he has to prime the pump, I'm wondering how I do this?

Venting and priming [ 2 Answers ]

Hello all. I am hoping this message will get to Speedball as he has already been involved and helped me earlier. Thanks, spirock Hi again Speedball You helped me earlier with my laundry room which has had an addition, and the sink and the washer and dryer moved. Per you previously #1) ...


View more questions Search