    We have a vertical water tower in our housing addition that fluctuates pressure from 50psi to 150psi.

    That has ballooned my water heater (gas) and caused it to leak. I replaced the water heater per code and am installing an overpressure bladder in series with the input cold supply to the water heater.

    This over pressure bladder is a metal 1 gallon container with a rubber bladder inside. It has a 3/4 input in one end and a schrader valve on the other end.

    I have put a 3/4 T on the input side but my question is: do I let some air out of the schrader valve? Do I add any air in the schrader valve? Or do I just leave the schrader valve alone?

    Thanks

    Hi

    This is my 3rd attempt at posting this question, hope it works this time.

    My housing addition uses a vertical water tank to supply pressure. The pressure fluctuates between 50 and 150 psi.

    That fluctuation has blown my hot water heater once now. This house is 8 1/2 years old.

    I replaced the water heater (gas) and am attempting to install an over pressure bladder in series with the cold supply line to the hot water heater.

    The bladder is around a 1 gallon capacity metal container with a rubber bladder inside. It has a 3/4 inch input end and on the other side of the tank is a schrader valve. I put a T on the input side but I don't know if I need to do anything with the schrader valve.
    Do I add air, release air as it fills with water, or just leave it alone?

    Thanks
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Jun 13, 2009, 10:53 AM
    my question is: do I let some air out of the schrader valve? Do I add any air in the schrader valve? Or do I just leave the schrader valve alone?
    Your expansion tank came precharged with 40 PSI. I'd leave it be. Good luck, Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

HIGH Pressure With Residential Well [ 1 Answers ]

My question is regarding very high water pressure with my residential well. My well is 600feet deep and I get superior water flow from all 4 outdoor faucets at same time & indoor at same time nonstop for 3 hours. One scenario is not being able to regulate my warm water in the washer. It is...

Low water pressure on residential well system [ 2 Answers ]

Hello, I have a residential well system and recently have some very poor water pressure. Here's the strange part(s): From my well I have a direct line that goes to a hydrant out at our barn. It has terrific pressure coming out of it. It is only the faucets, showers, etc. in the house that...

How to charge for residential pressure washing in So. Cal [ 1 Answers ]

Just added pressure washing to my Window Cleaning Business and wanted to know if anyone would be kind enough to share some standards on how to charge for pressure washing. I know this is a broad question. To be more specific, how do you charge for general P/W of a house, flat surfaces, i.e....

Residential Bladder Pressure Water Tank [ 1 Answers ]

I live in a rural area and my home is supplied by a well with a submersible pump. The water comes into a bladder pressure tank. I have noticed that when the shower or the dishwasher is running, the switch for the submersible well pump keeps switching off and on. I am worried that I will burn up...


View more questions Search