Ask Experts Questions for FREE Help !
Ask
    geraldn172's Avatar
    geraldn172 Posts: 1, Reputation: 1
    New Member
     
    #1

    May 29, 2009, 09:36 AM
    Well water pump
    I have a well an lately it seem as though the pump I turning on more than it should. I have a 30 gal expansion tank and when my wife runs one faucet for acouplle of minutes the pump cycles about three times. The tank is about 20 yrs old an I was wondering if the bladder in the tank was bad.
    jlisenbe's Avatar
    jlisenbe Posts: 5,020, Reputation: 157
    Uber Member
     
    #2

    May 29, 2009, 10:23 AM

    Probably. Depress the air valve at the top for a few seconds. If water comes out, then it's toast. Replacement is generally the only option. You can also watch the pressure gauge while a couple of faucets are on. You will probably note the pressure dropping and then recovering in just a matter of a few seconds instead of several minutes as it should be.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Breaker for underground water pump trips when a large volume of water is used [ 2 Answers ]

The breaker for the pump trips when the washer fills. Washer repair person said it is not the washer and pump repair person said the pump is working correctly. Breaker does not trip every time. Could it be a bad breaker?

DMAND Water Pump with Tankless Water Heater [ 9 Answers ]

Thinking of purchasing a DMAND water pump which, supposedly, will bring hot water to my faucet 3-5 times faster than it does now. Right now, it takes about 90 seconds of running the faucet to get hot water to my kitchen sink. Does anybody out there know how well this system works with a tankless...

Oily or 'hot' smell coming from water after replacing well water pump [ 2 Answers ]

My husband and I had to replace our water pump after it ceased and died on us this past Friday night! Ever since we replaced the well pump with a new Gould 1/2 hp we have been noticing an oily or hot smell coming from our taps... doesnt matter if it's the kitchen or the bathroom sink or...

AC Water Pump not sending water through tubing [ 1 Answers ]

My house is a ranch house with no basement. We have a forced air/central air conditioning system. There is a pump that is suppose to pump the water through a plastic tubing in to our laundry tub. The water does have to go up to the ceiling of the room and across a wall and then down into our...