    jonmoore's Avatar
    jonmoore Posts: 5, Reputation: 1
    New Member
     
    #1

    May 20, 2009, 02:25 PM
    Meyers Model HJ75S
    We have a Well Water Pump that was working fine this morning. Went to shed to start laundry and it drained the tank and expected the pump to kick back on but it did not.
    We replaced the Electrical Pressure 30/50 PSI switch and all it is doing now is hum. We checked the electrical wires with a meter and it is hot. The only sound we are hearing is a hum, sounds like it is from the switch. The pump does NOT come on at all.

    What do we do now?
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    May 20, 2009, 03:16 PM
    The first thing I would recheck is the wiring. Sounds like you're attempting to run a 220 motor on 110 or half a leg. Let us know what you find. Good luck, Tom
    jonmoore's Avatar
    jonmoore Posts: 5, Reputation: 1
    New Member
     
    #3

    May 20, 2009, 03:45 PM

    The only thing we changed was the Switch. The pump was already in existence and wired.
    mygirlsdad77's Avatar
    mygirlsdad77 Posts: 5,713, Reputation: 339
    Plumbing Expert
     
    #4

    May 20, 2009, 04:48 PM

    This is an above ground pump right? IF so, it may have a bad capacitor. Either that, or the pump is seized up. If you can post a pic of the pump, I will try to help you locate the cap.
    jonmoore's Avatar
    jonmoore Posts: 5, Reputation: 1
    New Member
     
    #5

    May 21, 2009, 10:49 AM

    I do not have the ability to post a picture. Where is the capacitor usually located?
    If the pump is seized up, what do I need to do?
    jonmoore's Avatar
    jonmoore Posts: 5, Reputation: 1
    New Member
     
    #6

    May 21, 2009, 10:51 AM
    Quote Originally Posted by speedball1 View Post
    The first thing I would recheck is the wiring. Sounds like you're attempting to run a 220 motor on 110 or half a leg. Let us know what you find. Good luck, Tom

    They had marked the wires to make sure they are connected to the same posts. The wiring is what was running on the last. We tested it with a meter to make sure the wires were hot and all of them are hot.
    mygirlsdad77's Avatar
    mygirlsdad77 Posts: 5,713, Reputation: 339
    Plumbing Expert
     
    #7

    May 21, 2009, 03:09 PM

    Usaully the capcitor is either located at the end of the motor under a removeable cover, or on top of the motor under a removable cover. If pump is seized, then you will need to tear pump apart from motor and see if it's the motor that's seized, or the pump itself. IF motor is stuck, then you will need a new motor, if pump is stuck you can order a repair kit which will include bearings and impeller with gaskets. Or just buy a whole new pump.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Kenmore elite model quiet guard 7 model 665. [ 12 Answers ]

Six month old dishwasher. Worked fine until today - won't start. LIghts are on and control panel seems to be working OK. The "Clean" indicator is flashing in intervals of 7 flashes and then pauses. When I select the "Start" button it flashes red 3 times and then nothing. The "Drain/Cancel"...

I'm replacing a white rodgers 1F58-72 model thermostat with a Hunter model 44155C [ 2 Answers ]

There are some different wiring codes that are different how do I do it.

Dennis is buliding a scale model he needs to find how tall will his model be? [ 3 Answers ]

Dennis is building a scale model of an office building. He has chosen to use a sclae of 1.0 in. = 15 ft. If the actual height of the bulding is 180ft, how tall will his model be?? :)

Growing Meyers Lemons from seeds [ 1 Answers ]

We have six (6) plant we started from seeds and they are doing just fine. Does anyone have any advice for us as the plants grow bigger?


View more questions Search