New Member
|
|
Apr 30, 2009, 09:32 PM
|
|
Old 4" Toilet Flange Soldered on; Keep it?
I'm in the process of remodeling a bathroom in a 45 yr old house. After remove the first layer of the subfloor, that I'll be replacing with newer plywood, backer board, and then ceramic tile, the old toilet flange sticks up about 3/4". It was just about the wood before removal. It would end up just about flush with the tile, maybe a little higher, but the toilet should completely cover it. The current flange is soldered to the drain, which turns after only dropping 1-2 inches.
Questions: Is it OK not to have the flange under the tile? Is fitting the backer board around the flange in two pieces OK (kind of a tile question I guess)? Are there any good reasons to cut off the old flange?
Thanks,
Mike
|
|
 |
Plumbing Expert
|
|
May 1, 2009, 12:22 AM
|
|
Don't cut the flange. Leave it the way it is. It is just fine to have it below finished floor. You can use extension ring to build it up to the floor level, or you can use "fat" wax ring to set and seal toilet.
|
|
 |
New Member
|
|
May 20, 2009, 02:04 PM
|
|
Mike,
I wasn't remodeling but when I was trying to fix my mother-in-law's toilet, I found the flange already below the floor level. I looked all over to find something locally then did a search and found a YouTube video for Toilet Flange Repair... There is this company at Set-Rite Products - Toilet Flange Spacer System that I ordered their Extension Kit. I would check out their video first but I wound up ordering a couple extra kits to put in my truck since they worked so great.
I don't believe in stacking wax rings or siliconing in those 'extenders' they sell at HD or Lowe's... eventually they are going to leak and do damage.
Hope this helps...
Tom
|
|
 |
New Member
|
|
May 20, 2009, 02:13 PM
|
|
Thank you for the suggestions. I like the looks of the Set-Rite product, if I end up needed to raise the flange. I've run into some slow downs in getting the tub plumbed, and have not got back to the floor yet. I'll put in a response when I finish with the floor..
|
|
 |
Eternal Plumber
|
|
May 20, 2009, 03:11 PM
|
|
Handy and Milo are correct. Leave the flange and use extenders.(see image) Good luck, Tom
|
|
 |
New Member
|
|
Aug 23, 2010, 11:45 AM
|
|
Well it took forever, and another upcoming relative visit, to get this project finished. But in the end the flange ended up slightly above the tile and a regular wax seal from True Value was fine. Since my floor was in really good shape, and not flexing at all, after installing 3/8" plywood on top of a 5/8" sub-floor, and screws every 6-8", backer board was not installed. A thinner membrane from Homelux for water protection was installed, and worked perfectly.
Thanks for all you suggestions, and I'll remember the Set-Rite product, for my next; got to be quicker, project... :)
|
|
 |
Eternal Plumber
|
|
Aug 23, 2010, 04:29 PM
|
|
Hey Mike,
Thanks for the update. We always like to hear back to see if we've helped. Good luck in the future. Tom
|
|
 |
Plumbing Expert
|
|
Aug 23, 2010, 04:34 PM
|
|
Glad you have tackled it down !
Good luck... and stop by if you need any advice in the future ! Milo
|
|
Question Tools |
Search this Question |
|
|
Add your answer here.
Check out some similar questions!
How to Install a Toilet when the Closet Flange is 1" Below Floor Level
[ 19 Answers ]
Hi Everyone,
I live in a two story house on a slab. Recently, I had a problem in my downstairs bathroom. The smell of sewer gases was coming in the bathroom even though the P-Trap in the sink and the trap in the toilet were full of water. After calling the city to check my sewer line for a...
Flange for 3" toilet waste line in basement
[ 11 Answers ]
My basement was already plumbed and ready to be finished when I moved into the home. However, the guys imitating plumbers, not only put the toilet waste line to close to the concrete wall (a problem I have already remedied) they also put a 3" main toilet waste line. Question: Are there flanges...
Replacing toilet flange when pipe 2 1/4" below floor
[ 4 Answers ]
I've got a 4" cast iron waste line with a slab floor. The pipe is 2 1/4" below the floor surface. The replacement flanges I have found are only 3" long. Is this 3/4" enough for a good seal? Does anyone know if there are longer replacement flanges out there? Thanks
Extending a toilet flange up 5"
[ 1 Answers ]
I have a bathroom in a garage apartment which floods every time we get rain. :( I am in the process of installing drainage lines, but the elevation difference between the back of the yard and the front is marginal. The way it rains around here, flooding is always a risk. To mitigate the risk, I...
Installing new toilet flange to 3" galvanized
[ 3 Answers ]
I'm installing a new toilet in a basement and the plumbing was roughed in back in the early 40's. The problem I having is trying to find the right flange that will work with 3" galvanized pipe. From what I can see I don't believe it's cast iron, but it wouldn't suprise me if it is. I bought a 3"...
View more questions