    May 8, 2009, 02:22 PM
    Why after titration of I- with S2O3(2-) using starh as an indicator a blue reappears
    When I titrated iodide with S2O3(2-) I used starch as an indicator, at equivalence the color changed to colorless. Then I left the solution aside after a while the blue color reappeared.
    Perito's Avatar
    Perito Posts: 3,139, Reputation: 150
    Ultra Member
     
    #2

    May 8, 2009, 02:33 PM

    Iodide was probably oxidized by the oxygen in air to iodine. The only other explanation is that there is a trace of iodine that was bound in some precipitate or something like that -- when that iodine was released, it reacted with the starch. I'm not sure if I can think of any other explanation.
    Unknown008's Avatar
    Unknown008 Posts: 8,076, Reputation: 723
    Uber Member
     
    #3

    May 8, 2009, 10:41 PM

    Or perhaps did some Iodine was on the inner wall of your flask, then it slowly came down, adding to the titrate more iodine, thus the blue colour reappeared.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search


Check out some similar questions!

Blue tablet put in tank of toilet, but no blue in the bowl [ 7 Answers ]

When a use a blue Vanish tablet in the tank of my toilet the water will not stay blue in the bowl. (No blue at all after flushing in one toilet, and only very light blue in another) I think this is because of the small tube that flows into the overflow tube goes directly into the bowl as clean, not...

Iodine clock reaction with S2O3 ion [ 3 Answers ]

In the iodine clock reaction with S2O3 ion I have found that one of the exponents in the reaction rate is 1.55. Can I round it to 2? Or shoud I write it as a fruction 3/2? I know that reaction rate can be a fraction. But it is a fraction in this case? Thank you! :)

Idometric Titration [ 1 Answers ]

have to find the molarity of an Unknown acid, but I was wondering how. I used this equation Cr2O7+14H+ + 6S2O3 = 2Cr + 3S4O6 + 7h2O We had to find the molarity of sodium thiosulphate which was 0.1M and K2Cr2O7 which was 0.02M for part A Part B This was an idometric titration the volumes used...

Redox Titration [ 1 Answers ]

How would I find the RMM of the unknown metal if the molarity of HCl = 0.1 M , NaOH = 0.1 The Metal was dissolved in 80 cm3 of HCL and titrated against 22. 74 cm3 of NaOH. The mass of the metal was 0.0686 g.


View more questions Search