    Head calculation of a pump
    How calculate total head provided by a pump
    sarnian's Avatar
    sarnian Posts: 462, Reputation: 9
    -
     
    #2

    Mar 25, 2009, 03:01 AM
    Hello samalmanas

    Here is a link to more information on head calculation of a pump.
    Quantum's Avatar
    Quantum Posts: 38, Reputation: 2
    Junior Member
     
    #3

    Mar 28, 2009, 05:58 AM
    I already answered a similar question in

    https://www.askmehelpdesk.com/mechan...la-313776.html
    1099's Avatar
    1099 Posts: 5, Reputation: 1
    New Member
     
    #4

    Jun 7, 2009, 02:18 AM
    Recirculating chilled water has three risers for a 110 ft. high building .The risers are terminated at a pump header.Risers are of different friction loss and velocity.Each risers supplies water to fcu anf ahu in the shops on floors.The total head loss is assumed at 120 ft.kindly guide us whether it will work properly.


    Regard
    1099
    1099's Avatar
    1099 Posts: 5, Reputation: 1
    New Member
     
    #5

    Jun 7, 2009, 02:27 AM
    Recirculating chilled water has three risers for a 110 ft. high building .The risers are terminated at a pump header.Risers are of different friction loss and velocity.Each risers supplies water to fcu anf ahu in the shops on floors.The total head loss is assumed at 120 ft.kindly guide us whether it will work properly.


    Regard
    1099
    nasarp's Avatar
    nasarp Posts: 2, Reputation: 1
    New Member
     
    #6

    Apr 25, 2010, 05:05 AM

    Recirculating chilled water has three risers for a 110 ft. high building .The risers are terminated at a pump header.Risers are of different friction loss and velocity.Each risers supplies water to fcu anf ahu in the shops on floors.The total head loss is assumed at 120 ft.kindly guide us whether it will work properly.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Pump head calculation formula [ 13 Answers ]

Send & explaine me pump head calculation farmaula

Pump head calculation for closed system? [ 1 Answers ]

Dear Sir/Madam, I want to know the chiller pipe pump head caculation for closed system?

Pump head calculation? [ 2 Answers ]

:mad: For pump head calculation Pipe length & pipe fitting details are ZIP FILE IS ATTACHED.

Pump head calculation [ 3 Answers ]

How do we calculate the pump head?

Pump head calculation? [ 3 Answers ]

The airconditioning air cooled chiller of 75tr are 2 no"s on second floor terrace level & AHU"s are at first floor level & each floor level height is 15 ft. totally there are 14 AHU"s. I want to know below specified calcucaltions? FOR CLOSED PIPE SYSTEM what is the pump head? what is...


View more questions Search