    Can a leaking copper water pipe be seal from the inside?
    I have a 3/4 inch copper pipe that is leaking in a spot very difficult to access. It rises vertically behind a masonry wall that would be a big job to go through to access the leak. It ends in an outside faucet for a garden hose. The horizontal line that it comes off continues on to feed 2 additional outside faucets. I could live without the one with the leak.

    Is it possible to
    1. Shut off my water main
    2. Cut the top off this copper pipe
    3. Thread an inflatable or otherwise potentially removable stopper about 3 feet down the pipe, below the leak but above the horizontal line which continues on to feed additional faucets.
    4. Test the repair by turning the water on to see if it is still leaking and if the 2 farther down faucets have not been blocked
    5. Remove reposition if there is a problem, otherwise
    6. Turn the water back off
    7. Fill the pipe above the stooper with something which would harden and permanently block the pipe. (ending the leak but losing that faucet)


    If so, what materials would be needed? Where can I get them? And do you know anyone on Oahu capable and willing to do this repair?
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Mar 26, 2009, 05:45 PM
    It rises vertically behind a masonry wall that would be a big job to go through to access the leak.
    Big job or not, that's exactly what I'd do. Take out the cement block, repair or cap off the leak and patch the wall. I was faced with the same problem with a line in my cement block house. It was on a outside wall. I broke the block, repaired the leak, patched and painted the hole and it looks great. Good luck, Tom
    letmetellu's Avatar
    letmetellu Posts: 3,151, Reputation: 317
    Ultra Member
     
    #3

    Mar 26, 2009, 07:35 PM

    There is a tool that is use to block water flow while sweating on a full flow ball valve. It is made like a test plug, has a rubber ball that has a bolt going through it, you insert the ball into the pipe you need to repair, and then tighten the bolt this squeezes the neoprene ball to the side walls of the pipe. Not you sweat on the ball valve and then slowly remove the tool, shut the ball valve and turn the water back on. I am not sure you could use this tool in what you want to do or not, it is just an idea.
    Milo Dolezal's Avatar
    Milo Dolezal Posts: 7,192, Reputation: 523
    Plumbing Expert
     
    #4

    Mar 27, 2009, 01:25 AM

    Cut the pipe before it enters the wall and when it surfaces on the outside. Rerout it where it is accessible. It is easy. Takes few minutes. Your approach is way to complicated.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Leaking copper shower pipe [ 17 Answers ]

Well, I just finished ripping out some tile and mixing some JB Weld. This morning I heard a hissing noise inside my shower wall. I ripped out a couple tiles and found a pin hole leak from a copper pipe inside my shower wall spraying the drywall. The house is about 20 years old and the leak is not...

Leaking copper hot water pipe in ceiling between in attic of 2nd story home [ 1 Answers ]

March 9th 2008, has leak in copper hot water pipe. Pipe is between the 2nd story ceiling and attic. Had is repaired by licensed plumber same date. New leak discovered today (a week later - March 16th) same copper pipe, but different location. About three feet removed from first leak. Home is...

Leaking copper pipe at joint [ 1 Answers ]

I have a slow leak from my supply pipe to my kitchen faucet. It's at the joint. I have copper pipes. What's the best way to plug the leak? Thanks very much

Copper Pipe Threads leaking [ 4 Answers ]

I just installed a new shower regulator after moving the copper piping. The solder joints are holding but the threads on one side of the regulator are seeping (about 1 drip a min). Looks like the teflon tape missed a thread to two... I can't take it apart and try again because it's affixed to...

Outside Pipe leaking Inside [ 1 Answers ]

I completely forgot to shut the water off for the outside water access from the basement for the winter. I finally did on Friday when it started to get much colder out. Now, the pipe (where the nozzle is) is dripping inside. My guess was, its because I wated so long, any of the water in the...


View more questions Search