New Member
|
|
Feb 21, 2009, 11:18 AM
|
|
Restarting well pump after fuse blown
Hi
My dishwasher was running when a fuse blew and the pump stopped. I reset the fuse but have no idea how to get the pump workling again, It is GE 5KCX36 model. The house is heated by hot water and it is Saturday in Canada. If it won't start, can I safely wait uuntil Monday to get a plumber?
|
|
 |
Uber Member
|
|
Feb 21, 2009, 01:07 PM
|
|
Aunt Kate! Good name since I actually had an Aunt Kate. At any rate, once you replace the fuse, the pump should start on its own. I was not able to locate your model number, but since you were able to see it, I am assuming this is a jet pump... above ground. If it doesn't simply start running once you replace the fuse, then you have some other problem. That might be the case since the fuse did blow.
If it does restart and run, but it's not delivering water, then it might have lost prime having been down so long. Shouldn't have, but might have. You can prime it by first removing the fuse to turn the pump off. Remove the plug (or possibly a pressure gauge) from the top of the pump housing. Pour in water until full, then replace the plug. Replace the fuse, and you should be in business.
Waiting until Monday won't be a problem unless it gets cold enough to freeze the pipes or pump.
|
|
 |
New Member
|
|
Feb 21, 2009, 01:25 PM
|
|
 Originally Posted by jlisenbe
Aunt Kate! Good name since I actually had an Aunt Kate. At any rate, once you replace the fuse, the pump should start on its own. I was not able to locate your model number, but since you were able to see it, I am assuming this is a jet pump...above ground. If it doesn't simply start running once you replace the fuse, then you have some other problem. That might be the case since the fuse did blow.
If it does restart and run, but it's not delivering water, then it might have lost prime having been down so long. Shouldn't have, but might have. You can prime it by first removing the fuse to turn the pump off. Remove the plug (or possibly a pressure gauge) from the top of the pump housing. Pour in water until full, then replace the plug. Replace the fuse, and you should be in business.
Waiting until Monday won't be a problem unless it gets cold enough to freeze the pipes or pump.
My favourite nephew!
The fuse I reset isn't in the pump but in a wall box. I suspect that you are right that one may be blown in the pump if not something else. It's a few degees below freezing here but ill try tonight and if it gets scary will have to pay a plumber to come on Sunday. In the old days we d leave a tap on but that won't work. I may put a space heater by the pipes and hope the place doesn't burn down!
Thanks again
|
|
 |
Uber Member
|
|
Feb 21, 2009, 03:06 PM
|
|
All is not lost. You are saying you have put in a new fuse and the pump still is not coming on? The problem might be in your switch. Do you notice a burned odor right at the pump?
BTW, I am not aware of any fuse in the pump itself. Do you know how old it is?
|
|
 |
Plumbing Expert
|
|
Feb 21, 2009, 04:26 PM
|
|
It is possible that you have a pressure switch with a lever that you will have to pry the lever slightly and hold it for a few seconds to get pump started.
Ive attached a pic of this switch, please let me know if your pressure switch has this.
|
|
Question Tools |
Search this Question |
|
|
Add your answer here.
Check out some similar questions!
Blown fuse in heat pump
[ 1 Answers ]
What are some causes of blown fuses in the inside unit of a heat pump? I had a blown fuse in the heat pump, replaced the fuse and the unit worked fine and heated the house up and blew the fuse again after an hour or so. I vaccumed out the inside unit sprayed contact cleaner on the contacts and...
Blown fuse
[ 2 Answers ]
I own a 1998 honda accord EX with an OEM factory alarm
Every now and then my alarm would start on its own. (Lights and horn on/off). One day I came to start my car and could not disengauge the park. Had to use shift release. The cruise control brake lights and horn would not work. When I...
Blown Fuse
[ 1 Answers ]
A brief background before the problem occurred. This morning I was caught in a traffic jam, wherein I had to idle the car for about 15 minutes. Thereafter the driving was normal until I stopped at a traffic signal for over 145 seconds. This time I had switched off the engine. I was unable to...
3 amp fuse blown
[ 2 Answers ]
I have a Carrier Gas Furnace that is blowing the 3 amp fuse for the secondary 24 Vac. I have replaced the fuse and after the heat is on for awhile the fuse will blow and then I have cool air blowing. Please advise on how to troubleshoot problem.Thanks
View more questions
Search
|