    Tap into 4" cast iron waste line with 2" pvc
    I want to add a sink in a dental lab as simply as possible.
    Can I cut a hole in an existing 4" cast iron waste line, fit 2" pvc to the opening and seal it with some kind of resin or wrap?
    Thank You,
    Vinny
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #2

    Jan 14, 2009, 03:45 PM
    Hi Vinny...

    Simplest way would be to drill the cast iron stack using a bi-metal hole saw and then use a SADDLE VALVE (see pics.) with ubolts and nuts to seal up the joint and allow you to have a PVC fitting to connect into. I would not go with any kind of sealant as pipe will be expanding and contracting so much from hot/cold water temp. differences that seal simply won't last.

    This, by the way, is not legal in terms of any plumbing codes, but it will install fast and get you up and running pretty quick off... if you can find the right saddle... ;)

    You will also need to add a STUDOR VENT (see last 2 pics. Below) to this sink UNLESS there are no other fixtures draining into the vertical pipe from above floors?? The studor vent gets set up like the last drawing, about 6-12" above the trap. This is ABSOLUTELY REQUIRED if there are fixtures draining into the stack from the above floors or the sink will not drain properly or should even be SIPHONED and allow sewer gasses to enter into the work area... not pleasant!

    Finally, I would prefer to see you do this by code and would be glad to talk you through this if you want, but if you are set on continuing to do this NOT BY CODE then this will at least be safer/healthier than a sealant that will crack over the long run.

    Let me know what you think here...

    MARK
    Attached Images
        

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Replace 1.5" galvanized steel (male threads) to 4" cast iron stack [ 1 Answers ]

I need to replace a drain line from an old double cast iron kitchen sink. The existing pipe is 1.5" galvanized steel which threads directly into female threads on a 4" cast iron stack. The male threads of the galvanized pipe broke off in the cast iron. I'm guessing the easiest solution is to...

PVC to cast iron waste line - odd size [ 16 Answers ]

Hello all. I recently stumbled onto this site and have found it very helpful in answering most of my plumbing questions. My current home fix-it project has hit a speed bump and I could use a little help/advice. I was replacing the worn (40+ yr old) faucet in my bathroom sink when I found that...

Cast Iron Waste Line [ 1 Answers ]

I have a 4" cast iron waste stack that connects directly to the sewer line exiting the house. The stack consists of three separate sections all with a bald and bell ends. Each is leaded into the next. I would like to remove two of the three sections and connect PVC into the remaining section so I...

Hairline fracture cast iron waste line [ 1 Answers ]

Here is the situation. I am installing a bathroom in the basement. Recently cut a section out of my 4 inch main line under the basement slab which is cast iron. The cast iron was installed in the 1930's and of course is old and brittle. Unfortunately, my first cut was made with a reciprocating...


View more questions Search