Bryant gas furnace model 383 KAV sometimes does not run
[ 6 Answers ]
I have a 10 year old Bryant gas furnace model 383 KAV that sometimes does not run. The inducer motor does not come on and there are no codes. If I cycle the power several times it will eventually all work normally at least until the next morning when it may or may not restart after being off at...
Bryant Furnace Plus 80
[ 2 Answers ]
Hi Experts, Can you guys please give me hand? Here's my problem, I have Bryant Furnace Plus 80, it's about 8yrs old. It worked so great until last week, the digital thermostat went dead, it didn't show any numbers on the screen, I thought maybe it's dead, so I went to the store and bought a new...
Bryant Furnace problems
[ 14 Answers ]
Hello everyone, I have a Bryant 80v furnace. Everything works fine till it is time for the blower fan to come on. I have opened it up, and the fan wheel turns freely. Checked the fuse on the circuit board no problems there. I been doing some reading about it all day long. The furance lights and...
Bryant gas hot air furnace
[ 1 Answers ]
I have a bryant gas hot air furnace model #397HAW036100. It has been nothing but trouble since day 1. here's my problem this year again. Purge fan kicks on gas valve goes on to pilot lights. Clicks on gas valve and pilot goes out. Does this about 6 times before it locks out. Last couple years... View more questions Search
|