    No Hot Water
    I have a Rheem Power Vent water heater, Model 21VP40E-1A. The fan is continues to run. The ignitor does not come on. No glowing or clicking. Do you know what the problem might be?

    Big_Sam
    Milo Dolezal's Avatar
    Milo Dolezal Posts: 7,192, Reputation: 523
    Plumbing Expert
     
    #2

    Dec 23, 2008, 09:44 PM

    Check if you have gas coming in...
    Big_Sam's Avatar
    Big_Sam Posts: 3, Reputation: 1
    New Member
     
    #3

    Dec 23, 2008, 09:56 PM
    Yes, I have Gas
    Big_Sam's Avatar
    Big_Sam Posts: 3, Reputation: 1
    New Member
     
    #4

    Dec 23, 2008, 10:09 PM

    Yes, I have Gas coming in
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #5

    Dec 23, 2008, 10:53 PM
    Could be a defective ignitor. Remove and look to see if it is cracked or use a ohm meter to test.
    hwheat's Avatar
    hwheat Posts: 13, Reputation: 1
    New Member
     
    #6

    Oct 1, 2009, 07:25 AM

    You also need to check your vacuum switch. Do this only if you are qualified.

    Your igniter won't light if your vacuum switch is not working.

    You can short the wires on your vacuum switch. All you need is a wire jumper or paper clip for this test. Turn the power off. Remove the leads to the vacuum switch and short the leads. Turn the power back on. If the gas works then, you may have a faulty switch or a plugged vacuum line or water in your line. If a plugged line, you can actually buy new line and run from the motor to your switch on the outside of the tank. Rheem recommends this.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Cold water coming out of hot water tap in bathroom but Really hot water in kitchen [ 7 Answers ]

Can anyone give me a reason as to why nearly completely cold water is coming out of my hot water tap in my bathroom but when I run the hot water tap in the kitchen the water is nearly boiling. The hot water and cold water taps are separate in the bathroom, where the kitchen has a handle which...

New hot water heater installed, but no hot water pressure. Plenty of cold water? [ 11 Answers ]

Hi, I own a small plumbing service and have a problem I've never encountered before. I installed a new top vented gas water heater for a customer. Turned the main back on, bled air out of the lines, etc. Problem is there is no hot water pressure throughout the house. Cold water pressure is fine....

Daylight basement water leak, cause by broken water pipe or saturated ground water? [ 1 Answers ]

I have a 6 units 3 stories with daylight basement apartment. Build in 1960. Just bought it few months ago. Last year the previous owner had a bad flood in the daylight basement after long period of rain. They cleaned out the area, remodel it. Good for few months, last couple of weeks rain long...


View more questions Search