    Water will not shut off
    I replaced a Kohler shower mixing valve to repair a leak. When I turn on the water to go to the new valve, the water comes out of the shower head and the Kohler handle will not control the flow or shut off the water.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Nov 19, 2008, 07:44 AM
    We need the model number of the valve.
    When I turn on the water to go to the new valve, the water comes out of the shower head and the Kohler handle will not control the flow or shut off the water.
    This is why I ALWAYS insist that the supplies and valve body be flushed out before reassembling a new valve. Turn off the water and open up the valve. Remove the cartridge and check and clean the inlet ports. Now turn the water on to flush uot the supplies and open valve body. Better now? Good luck and thank you for rating my reply. Tom
    Milo Dolezal's Avatar
    Milo Dolezal Posts: 7,192, Reputation: 523
    Plumbing Expert
     
    #3

    Nov 19, 2008, 08:22 AM

    Looks like either cartridge was not put in correctly ( was not lined up with notch ) or handle is not engaging meaning it is not attached properly.
    plumbingweaknes's Avatar
    plumbingweaknes Posts: 5, Reputation: 1
    New Member
     
    #4

    Nov 19, 2008, 06:31 PM

    The first time I put in a new shower mixing valve I forgot to remove the cartridge before soldering and the heat obviously warped the seals. Embarrassing...

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Hot water coming from cold side tap even though hot water supply shut off [ 2 Answers ]

Hi I been having problem for past year now hot water comes from the cold side tap, I only have 1 tap that shares water hot and cold the other 2 I have are 2 separate hot cold and 2 are just cold taps now I have even shut the cold water supply to the hot water tank off, but yet when I run the...

Low water pressure after water main shut off value was replaced [ 3 Answers ]

I changed the water main shut value and now I have low water pressure, I also made sure that the arrow on the value was going in the direction of the water flow

Can one shut off water main valve but leave gas hot water tank on? [ 4 Answers ]

I would like to know if I go away for two days and shut my main water shutoff valve can I leave my gas hot water tank on. I saw two answers To a similar question and one answer said you can leave it on and the other Said you had to shut it off. I am confused now as to whether I can leave the gas...

Can I shut off water supply to leaking hot water tank? [ 1 Answers ]

Can I shut off water supply to leaking hot water tank?

Hot water shut off valve and main water line [ 8 Answers ]

I was in my way to replace faucet for basin, but my local hot water shut off valve is not working. So now I have to shut off water supply from main line. Where would that be? I have old house and my water meter is out side. Also how to change shut off valve?


View more questions Search