    Transformer shorted out
    A friend of mine helped me cleaned my heat/cool unit. He moved it away from the wall. He took all of the wiring off and made a sketch in order to rewire it the same way. He also mentioned to me that he had seen the thermostat kind of loose so he wiggled it and he saw some loose wires so he then proceeded to open it up and rewired it. When he turned the unit on, the transformer shorted out. I then replaced the transformer but it shorted out again. What can be causing this problem??
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Oct 14, 2008, 04:56 AM
    The transformer keeps shorting out means that something is wired incorrectly. If you cannot find the problem I suggest you call a professional of a ON SITE inspection.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Shorted out pool pump motor - c48k2n143b1 [ 4 Answers ]

When I found my pool pump not working and no power, I checked the breaker. It had been tripped so I turned it on. There was a loud pop and then a little smoke came out of the end of the motor. Now - nothing. Aside from 5 days of rain, I can't explain what might have caused the problem. Is the...

Thermostat in furnace shorted out [ 1 Answers ]

I live in an older home that is 15 feet from the light rail tracks. Last winter the furnace kept shorting out (an older furnace and replacing not an option) there was a wire that would loose contact with the metal plate and we would have to manually shift it around to get the furnace to switch on,...

Lennox heat pump shorted out? [ 2 Answers ]

Hi! I hope someone can help me with this. Our Lennox unit is 13 years old and the circuit breaker for the compressor outside started going off. Every time I reset the breaker, it would blow again. I went out to the compressor, pulled the safety plug and then the circuit breaker would not blow. ...

Range receptacle shorted out [ 2 Answers ]

I have accidentally spilled a large amount of water on my electric stove top. So much that one of the receptacles threw sparks and now does not work. The heating element is fine.I have done some research and I think that I need to replace somethng called an infinite switch. Does that sound like...

68 camaro shorted out? [ 1 Answers ]

Okay then. I am stressed. I have a 68 Camaro with a 350 and Summit HEI. Like a rookie idiot I ran it without the external voltage regulator hooked up and fried something somewhere. I seem to have a short somewhere because when I put the key in the ignition (new yesterday), sometimes I get the...