    Sep 18, 2008, 02:15 PM
    Furnace blower
    The blower to my furnace will turn on and blow cold air for like 30 seconds and then shut off and the furnace isn't running. When the furnace kicks on it runs fine.
    acetc's Avatar
    acetc Posts: 1,004, Reputation: 79
    Ultra Member
     
    #2

    Sep 18, 2008, 08:10 PM
    Is this an old furnace with a standing pilot ? If so the fan switch may need adjusting, this control is in the area above the burners and will have a round dial with arrows, move the on pointing to around 130 up about 5 degrees and see if that cures your problem , this is the temperature that it turns the fan on, Good luck, Mike

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Furnace blower [ 1 Answers ]

My furnace blower will not run at full speed when the thermostst is on the auto setting but it will run at full speed when in the on setting what could be my problem

Furnace blower [ 1 Answers ]

When the thermostat is off why does the furnace blower continue to run?

Furnace goes out when blower comes on [ 1 Answers ]

Furnace goes out when blower comes on

Furnace blower hum [ 1 Answers ]

I have a Trane XE 90 gas forced air furance which is about 10 years old. When the blower kicks on there is a humming noise which then goes away after a few seconds. It is rather a loud noise. What can be done to prevent this noise?

Furnace Blower [ 3 Answers ]

Two months ago I noticed furnace blower would switch off after being on a couple of minutes. Once I heard some humming, thought it was the motor. Had a techinician diagnose it, he said it was the blower motor, a $400 repair. I pulled it out myself, took it to a electric motor shop. They put...


View more questions Search