    PVC vs CPVC Solar Water Heater
    I constructed a solar water pre heater for my water heater and after a day the many of the fittings started to leak. The local HD said regular PVC probably would be OK, but apparently it was not. Little did we know the water got up to 140 deg F inside the PVC, which I had painted black. I am wondering if CPVC will work - CPVC is supposed to be rated at 180 deg F and I just have normal household water pressure. Back to the drawing board. Solar Pre Water Heater
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #2

    Jul 14, 2008, 03:40 PM
    Hey.. great idea! Painting was critical to success!

    Yeah... PVC pipe is rated to not exceed 140 degrees F so seems you got some bad info... but let me ask.. did you PRIME and cement your fittings and pipe? This can make a HUGE difference in joints holding...

    You will definitely be better off with CPVC pipe/fittings as it is rated to not exceed 180 degrees F. Be sure to use the correct primer and cement or you will be back here unhappy again... ok? Just be sure that whatever type of cpvc you choose, you choose the right primer (if needed) and cement.

    Check out this link below:

    CPVC Products - Frequently Asked Questions

    Unfortunately, you will need to paint with a good quality latex paint to reduce harm from UV rays... ;)

    Let us know if need more information... good luck with it! Looks like a great setup! Our friend HKSTROUD will love this... :)

    MARK
    JackTheBearTexa's Avatar
    JackTheBearTexa Posts: 3, Reputation: 1
    New Member
     
    #3

    Jul 14, 2008, 07:55 PM
    Thanks for the response - I actually looked at the website you suggested today.
    I did prime every joint with the purple primer and thought I had glued them well. Let them set for more than 24 hrs AND I plumbed my entire house with PVC and CPVC and never had a leak. Now I make this thing and it had about 15 or more seeps and leaks and I can only attribute it to the use of PVC and it's components. Will do a row in CPVC and see how that goes. I think the temp probably exceeded 140 deg and it just failed in many places. Never saw anything like that. Oh I used brand new glue and primer. Will keep you posted. Thanks for your help.
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #4

    Jul 15, 2008, 03:52 AM
    Glad to help anytime Jack...

    Thanks for updating me... good luck, really neat idea here!

    PS... what new cement and primer did you use? New stuff on pvc.. or new stuff on cpvc?. just curious?

    Thanks... MARK
    JackTheBearTexa's Avatar
    JackTheBearTexa Posts: 3, Reputation: 1
    New Member
     
    #5

    Jul 15, 2008, 07:08 AM
    What I meant was, I used fresh, new primer and Oatley Gold PVC cement. I just think the heat got it. The glue softened and then the joints separated. 140 deg F + did it in. Thanks again - back to the HD for CPVC pipe, primer and glue. Will just do one row and give it a test before investing another $100. Guess I can use the 3/4 for a lawn sprinkler - ha. PS - The PVC and CPVC in my house has held up since installation in 1982 - 26 years! No leaks, no problems. House H20 is about 120 deg F.
    Cheers
    JackTheBearTexas

    Well I took out the PVC and replaced it with CPVC. Let all joints cure overnite and all looks OK. Just used the same box and about 100 ft of CPVC. Of course I did prime and use CPVC cement. Water temp at a trickle - 130 deg. Have placed glass over the top of the enclosure, but sun going down - Was up to 130. Will check tomorrow. If it holds under pressure, will purchase 2 or 3 hundred feet more and give that a try. Oh, I did paint it flat black. I hope it works - the water temp going into the water heater is higher than the normal hot water temp. Should save a little gas if we remember to use hot water appliances during the day time. Thanks for your help - will update if all goes OK. Cheers JackTheBear

    Quote Originally Posted by JackTheBearTexa
    I constructed a solar water pre heater for my water heater and after a day the many of the fittings started to leak. The local HD said regular PVC probably would be ok, but apparently it was not. Little did we know the water got up to 140 deg F inside the PVC, which I had painted black. I am wondering if CPVC will work - CPVC is supposed to be rated at 180 deg F and I just have normal household water pressure. Back to the drawing board. Solar Pre Water Heater
    Finally got the solar heater running and it is putting out really hot water - Check out the finished product (well I have to spiff it up some) at Free Hot Water - Really Hot Water!
    Thanks for all your help - I have to write on the "blackboard" one hundred time "PVC for cold water, CPVC for hot water"
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #6

    Aug 31, 2008, 09:15 AM
    Too late now but I would have considered ridgid copper or even flexible copper tubing. It convects heat much better/faster than CPVC. You must live in a place where freezing is not going to be an issue, right?
    jaketeater's Avatar
    jaketeater Posts: 2, Reputation: 1
    New Member
     
    #7

    Nov 18, 2009, 05:09 PM
    I used PVC for my water heater and so far have had good results. I did a couple things differently. My heater was a thermosyphon under very low pressure. This meant that the water in it was constantly circulating. I also insulted all of the PVC connections so that they would be protected somewhat from the heat. To check out my design just follow this link:
    http://solarhotwater.teaters.com
    Milo Dolezal's Avatar
    Milo Dolezal Posts: 7,192, Reputation: 523
    Plumbing Expert
     
    #8

    Nov 18, 2009, 09:24 PM
    Quote Originally Posted by jaketeater View Post
    I used PVC for my water heater and so far have had good results. I did a couple things differently. My heater was a thermosyphon under very low pressure. This meant that the water in it was constantly circulating. I also insulted all of the PVC connections so that they would be protected somewhat from the heat. To check out my design just follow this link:
    http://solarhotwater.teaters.com
    Hello in Brazil. I spent 3 weeks in Brazil last November and loved it there, especially the people. I didn't see that shower head as it is presented in your video but I saw similar thing in Perú.

    I like what you've done. But just wonder why you didn't use copper for the coil. You cannot get maximum heat out of PVC. Also, I would suggest to put sheet of galvanized sheet metal on the bottom of the solar box, than manifold painted black and cover it with glass top. It works magic even in winter time...

    I built it this way for my pool. I never used heater afterwards.

    But overall, I like your attitude. We need people like you ! Not in Brazil - but here in States ! :D

    Best regards ! Milo
    jaketeater's Avatar
    jaketeater Posts: 2, Reputation: 1
    New Member
     
    #9

    Nov 19, 2009, 05:02 AM

    I priced copper - and its just too expensive here in Brazil. The whole thing cost less than $500 (solar collector, water tank, glass etc). With the price of copper I would have spent more that $500 on just the copper.

    The galvanized sheet metal - Yeah, I wish I would have done that. The bottom is plywood, then 1 inch of styrofoam, then black plastic. The styrofoam is already warping and the black plastic is tearing. Oh well, live and learn. That's what this heater was for anyway, we plan to put one on the orphanage I work at, this was solar heater 1.0 beta.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Connecting a tankless water heater and separate hot water heater [ 6 Answers ]

What I have is this. An oil fired boiler that generates hot water for my house baseboard heating system. Contained within the boiler is a tankless heater that is heated by way of the firebox in the boiler. The tankless heater is used only for domestic hot water. It has a separate CW supply to the...

Whole house water supply copper to cpvc [ 2 Answers ]

I recently bought a house with a private well . The previous owner never had any type of water treatment or filter system on the water supply. Because of this all the 1/2" copper tube is lined with sediment and sludge restricting the flow to all faucets and outlets. There is already some 3/4" cpvc...

Wrong cement used to join CPVC water pipes. [ 4 Answers ]

A few months ago, in our new addition, I plumbed an upstairs 3/4 bath in CPVC. I used purple primer (designated for PVC and CPVC) and used clear, medium bodied cement designated for PVC to make the joints. I just realized my error. The walls are still open. My question is, do I have to...

How to repair a leaky cpvc water line under the sink [ 1 Answers ]

Don't think joints of line have any threads, looks like a coupling just fits over the pipes. Help.l


View more questions Search