    Shower runs when tub run is running - the good ol diverter Q
    Hi, I have installed a new Delta mixer system that feeds the shower and tub and when the tub is on the water trickles out the shower head. When the shower is on there is no issue with the tub leaking.

    I am using 1/2" pex tubing for the pluming from the mixer to the shower/tub.

    When I take the tub spout off the issue is not as severe but only takes a slight pressure change (like me placing my finger over the end) before it starts to drip.

    Could it have something to do with the distances they are from the mixer? I believe I am in the guidelines set out on the Delta website.

    Any thoughts would be greatly appreciated.
    Also forgot to mention the diverter pin is located on the mixer assembly not the tub spout.
    Thanks!
    Milo Dolezal's Avatar
    Milo Dolezal Posts: 7,192, Reputation: 523
    Plumbing Expert
     
    #2

    Aug 29, 2008, 03:53 AM
    You may have too much pressure in your system. It think water pressure should around 55 psi. Your "problem" should have nothing to do with "distance".
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #3

    Aug 30, 2008, 08:49 AM
    Could it have something to do with the distances they are from the mixer?
    The distance between the mixer valve and the shower head has everything to do with it. Read on. There are three reasons that shower heads leak. 1) a faulty diverter, 2) Excessive house pressure and 3) Too short a shower raiser.
    The average house pressure's 45 PSI, (that's why water towers are 100 feet tall). You should have about 27" of raiser from the mixing valve to the shower head. Good luck, Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Blower runs only 2 minutes but A/C compressor keeps running [ 1 Answers ]

The blower which pushes either cold air through the house as part of the central air conditioning only runs for about 2 to 3 minutes at a time. Then it shuts off. The Lennox compressor unit outside though, runs continuously. After a while (about 10-15 minutes) the blower turns on again. Is it...

Craftsman tractor engine runs good but no power to move [ 1 Answers ]

I have a Craftsman tractor 42in deck hydrostatic, while cutting the lawn the other day I was going up a slight incline(that I always mow) and the tractor lost its power to go forward essentially. It rolled down hill and actually tipped over. Now when I start the tractor the engine is fine but it...

Running blower at slow speed all the time, and high when compressor runs. [ 1 Answers ]

I have a Carrier 58PAV090 furnace air handler. The fan has multiple leads which are used to run the blower at different speeds. The black is for High speed, yellow for medium high, blue for medium low and red for low. In the cooling mode, the blower turns on when the thermostat calls for cooling...

Water runs for 30 seconds and then stops running [ 8 Answers ]

For 5 days now whenever we turn on a faucet the water runs as expected for maybe 30 seconds and then just quits running. This is happening in the kitchen, shower, washing machine, basically everywhere in the house. We live outside the city limits and just recently started receiving 'city' water...

Bath tub shower spout & head running water running at same time [ 1 Answers ]

I started with a slight dripping problem(sayko system).i decided to replace all 3 stem assemblies together as they all were about 18 years old.after reassembling the new stems(danko brand),turned on the water supply & checked faucets.hot & cold worked fine but when the shower was turned on,water...


View more questions Search