    Strange noise from main water valve
    I live in a 2 story 5 year old house on a community well. Just recently, we noticed a banging noise when a toilet is filling up or when multiple faucets are running at the same time. The sound is coming from the main valve where the water comes into the home (a closet). I made sure it was all the way open.. Everything seems to be working fine, it is just a very loud annoying sound. We also noticed the water "pulses" during this sound like it's not a steady flow. Any thoughts? Thanks
    hkstroud's Avatar
    hkstroud Posts: 11,929, Reputation: 899
    Home Improvement & Construction Expert
     
    #2

    Jul 11, 2008, 01:41 PM
    Loose washer in main shut off valve. Turn off water to house, remove valve stem, tighten washer, reinstall stem.
    Milo Dolezal's Avatar
    Milo Dolezal Posts: 7,192, Reputation: 523
    Plumbing Expert
     
    #3

    Jul 11, 2008, 07:17 PM
    Go to each of your plumbing fixture in your house and turn off and on angle-stops. ( on and off valves ). Also, go to your pressure regulator with pair of pliers and 1/4 turn the pressure adjustment bolt.
    hkstroud's Avatar
    hkstroud Posts: 11,929, Reputation: 899
    Home Improvement & Construction Expert
     
    #4

    Jul 12, 2008, 05:21 AM
    Private message received from Tim.
    "Do I shut off the water at the street or in the house where the noise is coming from?"

    You would turn it off at the street, but before doing that do as Milo suggest and adjust your pressure regulating valve slightly up or down if you have one.

    PRV will look something like this.
    Attached Images
     
    afaroo's Avatar
    afaroo Posts: 4,006, Reputation: 251
    Ultra Member
     
    #5

    Jul 12, 2008, 07:37 AM
    What is considered normal water pressure? There really is no such thing as "normal" water pressure. Since water pressure is influenced by the elevation of the reservoir that serves your neighborhood versus the elevation of your water meter, water pressure varies from property to property. Water pressure in the District typically ranges from 45 - 125 psi; however, typical residential systems are designed to function best under a pressure of 40 - 60 psi. If the water pressure entering you home exceed this level, you should install a pressure regulator in the line to reduce the pressure to an acceptable range. This protects your equipment and piping in your home from damage from excess force exerted by the water. Symptoms of high pressure include "clanging" or "rattling" of pipes that occur when a faucet, dishwasher, or washing machine shuts off; water heater pressure relief valve malfunctions, and reoccurring leaks. The symptom of low pressure is typically a noticeable reduction of flow.

    If you need to do any adjustment to the pressure regulator please use pressuer test gauge, Thanks.

    John
    Attached Images
  1. File Type: pdf Watts Water Pressure Test gauge.pdf (327.4 KB, 252 views)

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Can one shut off water main valve but leave gas hot water tank on? [ 4 Answers ]

I would like to know if I go away for two days and shut my main water shutoff valve can I leave my gas hot water tank on. I saw two answers To a similar question and one answer said you can leave it on and the other Said you had to shut it off. I am confused now as to whether I can leave the gas...

Strange water noise [ 2 Answers ]

Water sounds like it is flowing though the pipes, but the water meter shows that there is no water usage. It is very lound where the pipes come into the basement. Could it be just pipe noise from water flowing though the main water main? This is a house that is only 5 years old. It is as loud as if...

Hot water shut off valve and main water line [ 8 Answers ]

I was in my way to replace faucet for basin, but my local hot water shut off valve is not working. So now I have to shut off water supply from main line. Where would that be? I have old house and my water meter is out side. Also how to change shut off valve?

Water main cut off valve [ 5 Answers ]

I live in a condo and while updating my bathroom I was turning off the hot water valve under the sink and it came off in my hand! I turned off the water main cut off valve located near the hot water tank. The cold water was off and I let the hot water run for almost 1/2 hour thinking I was...

Gas valve noise on main valve engagement [ 1 Answers ]

I have a carrier 58gs100ga furnace with a white rodgers 36e93 gas valve. The main gas valve solenoid chatters or rattles for a split second before it stays engaged after the pilot is proved. I just replace the spark/lock out board and the fan board for a different problem. This chatter is...


View more questions Search