    #1

    May 17, 2008, 10:38 PM
    I bot a pfister(Treviso 808dc)... to replace my tub valve body. The problem: the hot/cold water inlets of the pfister do not align with my incoming hot/cold pipes. Whereas the pfister has the outlet and inlets 'together' my outlet is behind the inlet-incoming hot/cold pipes-(about 2.5 inches). My existing valve body is 10 yrs old.
    Two other questions:(1) Does pfister or are there any other brand that is compatible with my valve?
    (2) What do I do to solve this problem? Is it possible to use,for example, 'S' connectors? Are there S connectors available? What connectors do you recommend?
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #2

    May 18, 2008, 08:07 PM
    Sharvani, I see you are new to AMHD so you probably did not know you can start your own post by clicking on ASK. When you jumping into someone else's post it can confuse us old farts. By the way, you will need to cut out some of the old piping and repipe to fit the pfister, its just like Moen and most of the rest.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #3

    May 19, 2008, 06:53 AM
    Go to; Plumbing and click on your valve for the information that you're looking for. Good luck, Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Installing a expansion valve [ 1 Answers ]

HI, I have a cental a/c in my home it is a york 3ton. The freon is controlled by an orfice. I was told that an expansion valve is much better. The reason for the change the system will not cool like I think it should. Even when it was new it did not work that well. I have a 1280sf raised ranch. I...

Installing a signal wire for a heat pump change over valve [ 2 Answers ]

My wife and I just bought a house and I was thrilled when I saw that the outside unit was a heat pump (a Goodman ck36-1b model, to be exact). Well, today was the first day that we were to run the heat, and I noticed that the furnace kicked on immediately. "Strange," I thought, "doesn't the...

Gas valve noise on main valve engagement [ 1 Answers ]

I have a carrier 58gs100ga furnace with a white rodgers 36e93 gas valve. The main gas valve solenoid chatters or rattles for a split second before it stays engaged after the pilot is proved. I just replace the spark/lock out board and the fan board for a different problem. This chatter is...

Installing a pressure balancing valve [ 1 Answers ]

I have a question regarding the installation of a 35.253.000 Grohsafe-enhanced flow pressure balancing valve. What it the recommended way of installing the valve to the 1/2" copper supply pipes? The shut off valves on the sides are 1/2-14NPT male X 1/2" copper sweat. Should I use brass drop ears on...


View more questions Search