    I only have enough room for a 2 3/4" concrete poor.
    Hello,

    I Was wondering if 2 3/4" of concrete is enough to poor over my shower vent in my basement? Due to poor placement of the main sewerline that sevices my home (right underneith my shower P trap) I have been unable to get more than 2 3/4" bellow the finished floor with my vent. The vent pipe is only this shallow for about 9" in length before rising into the wall and is located about 9" from the toilet flange toward the side wall so there will be little traffic in this spot. Will it crack? What's the best mix to use to get the best strength? Will the concrete damage the black abs? Can I use a mechanical vent for shower, toilet and lav together? 2 3/4" is from the top of the vent pipe at its highest point.
    I was planning on using slip and spacing material between the pipe and concrete. Lanolium finished floor.

    Thanks,
    Rich
    Clough's Avatar
    Clough Posts: 26,677, Reputation: 1649
    Uber Member
     
    #2

    May 18, 2008, 12:57 AM
    I think that your question could also really benefit from the expert input and advice from one of our most experienced, veteran plumbing experts here, and that would be speedball1. As such, I have already notified him about your post.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #3

    May 18, 2008, 04:20 AM
    Good morning Rich,
    (1)Will it crack? (2) What's the best mix to use to get the best strength? (3) Will the concrete damage the black abs? (4) Can I use a mechanical vent for shower, toilet and lav together?
    1.) No. 2.)Regular cement mix. 3.) When we run water pipes through cement we insulate them with Armoflex and if drainage is to be run in cement er cover the pipes with roofers tar paper. 4.)Yes, if local codes allow, check with your Building Department. Good luck, Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Circuit breaker OK, but no electricity in living room/dining room [ 5 Answers ]

I have a 100 year old farm home. The lights went out in living room and dining room Thanksgiving night. The circuit breaker appears normal and the panel is OK. What went wrong?

AC Flow in one room very poor [ 1 Answers ]

I own a three story townhouse. The central AC unit is on the bottom floor, but there is one particular room at the top level where the air flow is very weak. This contributes the room being very hot in the summer time, and very cold in winter months. I was told by my home-warranty program that I...

Broken Concrete trap "Drainage Pipe" [ 1 Answers ]

I recently bought a house with a unfinished basement bath. I have since decided to finish the bathroom but have ran into a bit of a problem. The previous owners set all of the drains up and I have since found a large hole in the trap of a secondary drain that drains into the main. To explain it...

No room for copper "T" [ 1 Answers ]

I need to install a copper "T" on a supply line, but I can't move the two halves of the tubing far enough apart to insert the "T". Was planning to use a compression fitting, but I could solder. The "T" will lead to a valve, be reduced, then go to the icemaker. Any suggestions?

Moving Bathtub across room on a concrete slab [ 1 Answers ]

I am considering changing the location of my bathtub. I'd like to replace it with a whirlpool garden-style tub, and move it over to another wall. On the new wall the drain end of the tub would butt against the existing freestanding shower. This would require breaking through the slab to...


View more questions Search