Ask Experts Questions for FREE Help !
Ask
    baybee's Avatar
    baybee Posts: 15, Reputation: 1
    New Member
     
    #1

    May 7, 2008, 07:20 AM
    No hot water pressure in tub spout
    I Have A Valley Shower Faucet Live In Mobile Home No Hot Water Pressure In Tub/shower, All Three Sinks Have Great Pressure. So Far I Have Drained A Gallon Of Water From Hot Water Tank. Shut Off Water Main Took Out Cartridge And Seats And Springs Turned Main Back On For 5 Min Looked At Faucet Still No Hot Water Pressure Even With Nothing In It. Held Finger Over Cold Water Hole To Flush Hot. Shut Off Main Put In Brand New Springs And Seats And A Brand New Cartridge Turned Main Back On.

    Still No Hot Water Pressure In Shower Don't Know What Else To Do??
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    May 7, 2008, 07:57 AM
    Still No Hot Water Pressure In Shower Don't Know What Else To Do??
    Renove the knob and chrome face plate and Look up where the hot water connects to the valve,(see image). This is a screwdriver shut off or integral stop. It's a shut off so you can service the valve. Shut the water off at the house shut off or the hot water heater and remove the stem and washer assembly from the screw driver stop. Feel around the seat for a blockage. Now turn the hot water back on to flush out the supply and screwdriver stop. Do you have a full stream now? Good luck, Tom
    baybee's Avatar
    baybee Posts: 15, Reputation: 1
    New Member
     
    #3

    May 7, 2008, 08:52 AM
    I do not have shut off screws looked. But I did do everything else you stated and no help
    Thanks
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #4

    May 7, 2008, 09:02 AM
    Quote Originally Posted by baybee
    I do not have shut off screws looked. but i did do everything else you stated and no help
    thanks
    OK! That puts the problem in the hot water supply. If I were there I would cut the hot water supply loose from the shower valve and disconnect the hot water supply from the lavatory faucet. I would then take a air compressor or air bottle and attach it to the lavatory supply and attempt to blow the obstruction out of the system. Good luck, Tom
    baybee's Avatar
    baybee Posts: 15, Reputation: 1
    New Member
     
    #5

    May 7, 2008, 09:10 AM
    Going to try that tomorrow cousin coming with an air compressor but we did not know how to go about using it to blow line, thanks will let you know how it works out.:)
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #6

    May 7, 2008, 09:21 AM
    Quote Originally Posted by baybee
    Gonna try that tomorrow cousin coming with an air compressor but we did not know how to go about using it to blow line, thanks will let you know how it works out.:)
    Your biggest hassle will be adapting the compressor to the lavatory supply. If you run into a problem click on back for a little help;. Cheers, Tom
    baybee's Avatar
    baybee Posts: 15, Reputation: 1
    New Member
     
    #7

    May 7, 2008, 09:22 AM
    Speedball one question before I attempt this tomorrow. If the hot water pressure is perfect in the lav sink -hot water supply than how will that blow blockage all the way to the hot water supply in tub.

    And any suggestions on what PSI to use?

    Thanks much:)
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #8

    May 7, 2008, 09:39 AM
    Quote Originally Posted by baybee
    Speedball one question before i attempt this tomorrow. If the hot water pressure is perfect in the lav sink -hot water supply than how will that blow blockage all the way to the hot water supply in tub.

    And any suggestions on what PSI to use?

    thanks much:)
    I'm closing the entire system off, ( shut the cold water off at the water heater and close all hot water faucets.)and pressuring up the entire hot water system through the lavatory supply with the terminal outlet being the tub/shower supply that you have opened up. This will force water back through the tub valve supply. It will be a weak stream at first but when the stream becomes strong chances are you blew the blockage out. I would start a 100PSI and go up. This might kick off the T&P valve on the water heater but it will only be for a short while. Let me know how you made out. Good luck, Tom
    baybee's Avatar
    baybee Posts: 15, Reputation: 1
    New Member
     
    #9

    May 7, 2008, 09:54 AM
    Thanks so so much I sure will let you know if it works. Keeping my fingers crossed:D
    baybee's Avatar
    baybee Posts: 15, Reputation: 1
    New Member
     
    #10

    May 7, 2008, 01:13 PM
    Hi was thinking your statement

    This will force water back through the tub valve supply. It will be a weak stream at first but when the stream becomes strong chances are you blew the blockage out

    How will water flow in a stream than strong through hot water line when hot water is shut off at water heater where does water come from?
    Thank you
    baybee's Avatar
    baybee Posts: 15, Reputation: 1
    New Member
     
    #11

    May 8, 2008, 07:11 AM
    Well my cousin wanted to try his way shut off main took out cartridge and seats/spings and is blowing air in the hot water 75 psi hole no improvement
    baybee's Avatar
    baybee Posts: 15, Reputation: 1
    New Member
     
    #12

    May 8, 2008, 07:20 AM
    Now using 100 psi blowing from hot water supply line on top of hot water heater no improvement
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #13

    May 8, 2008, 07:30 AM
    Quote Originally Posted by baybee
    Hi was thinking your statement

    This will force water back through the tub valve supply. It will be a weak stream at first but when the stream becomes strong chances are you blew the blockage out

    How will water flow in a stream than strong through hot water line when hot water is shut off at water heater where does water come from?
    Thank you
    The water wii come from the water remaining in the pipes
    Well my cousin wanted to try his way shut off main took out cartridge and seats/spings and is blowing air in the hot water 75 psi hole no improvement
    Now using 100 psi blowing from hot water supply line on top of hot water heater no improvement
    Since your cousins method didn't work, (he provided no terminal outlet) now give my way a try. Good luck, Tom
    baybee's Avatar
    baybee Posts: 15, Reputation: 1
    New Member
     
    #14

    May 8, 2008, 07:40 AM
    With water main shut off and hot water heater on hot water burst out good with water main back on cold water burst out and hot water went down to a trickle
    baybee's Avatar
    baybee Posts: 15, Reputation: 1
    New Member
     
    #15

    May 8, 2008, 07:53 AM
    Do you mean by terminal outlet an open faucet?
    With water main shut off and hot water heater on hot water burst out good with water main back on cold water burst out and hot water went down to a trickle
    baybee's Avatar
    baybee Posts: 15, Reputation: 1
    New Member
     
    #16

    May 8, 2008, 09:04 AM
    OK just did exactly what you instructed. Not much pressure to terminal supplu but we than reversed and sent air from terminal supply (tub) to lav and great pressure does not make sense?



    Quote Originally Posted by speedball1
    The water wii come from the water remaining in the pipes

    Since your cousins method didn't work, (he provided no terminal outlet) now give my way a try. good luck, Tom
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #17

    May 8, 2008, 10:10 AM
    It means that you blew the clog into another branch. Does the tub valve have pressure or is there still a problem?
    baybee's Avatar
    baybee Posts: 15, Reputation: 1
    New Member
     
    #18

    May 8, 2008, 11:54 AM
    You are not going to believe this as I said I live in Mobile Home after hours of frustration hope this helps someone else with same problem, my cousin cut out the wall behind shower and about 12 inches down from hot water supply connection was a SHUT OFF VALVE and the cold water also has a SHUT OFF VALVE in between the WALL where no one could ever see or reach or touch?? Crazy or what?
    This home built my Keiser.

    Seem the hot water shut off valve was not fully open some vibration must have turned it (only a guess). Any way now have perfect hot water pressure but 2 big holes in my wall.

    Going to repair it with a door haha
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #19

    May 8, 2008, 12:17 PM
    Back in the 70's I worked as a plumber in mobile home factories in my area. (not Kieser) Lots of mistakes going out the door that are picked up when the unit's set up and .ready to be occupied. Sometimes they're missed, like yours. Glad you located the trouble. Give because a pat on the back for a job well done and buy him the best steak in the house. Regards, Tom
    baybee's Avatar
    baybee Posts: 15, Reputation: 1
    New Member
     
    #20

    May 8, 2008, 02:34 PM
    Thanks so much just hope this helps someone else in the same situation.
    Have a good one

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Water leaking from tub spout [ 1 Answers ]

Please help. I do not know what I am doing wrong. I went through three tub spouts trying to solve the problem I am having. When I install the spout, everything is fine when you turn the water on. When you pull up the diverter for the shower, water leaks out of the hole in the bottom of the...

Leaky spout after water is turned off [ 1 Answers ]

I recently fixed leaks in my tub spouts by replacing the springs and washers. The thing I would like explained is this: I first turned off the water in my house and replaced the parts in the faucet handles. While the water was still off the faucets were still leaking and one of them was...

Leak in shower about water spout [ 2 Answers ]

I was looking over the answers to plubming for shower/tub. Our leak is just above the water faucet. It leaks out where the plumbing was welded. Can't figure how to get it out.

Sprayer has pressure, spout does not [ 16 Answers ]

This is the greatest forum I've ever seen! My fiancé and I recently bought a condo and the kitchen sink has virtually no water pressure in the spout, but the sprayer has full pressure. I have never done any plumbing at all in my entire life, so tonight I took a crash course. I got under the...


View more questions Search