    Goodman furnace will not ignite
    :confused: I just bought this goodman furnace Followed the directions to convert it to lp gas. Put it on so the heat will kick on. The blower blows and the ignitor glows but doesn't ignite the flame. Now I lit it with a torch it lights but it is a horrible yellow flame. Does anybody have any advice thank you people
    ksduster's Avatar
    ksduster Posts: 5, Reputation: 1
    New Member
     
    #2

    Nov 17, 2007, 03:44 PM
    Quote Originally Posted by chopchop
    :confused: I just bought this goodman furnace Followed the directions to convert it to lp gas. put it on so the heat will kick on. The blower blows and the ignitor glows but doesn't ignite the flame. Now I lit it with a torch it lights but it is a horrible yellow flame. Does anybody have any advice thank you people
    Hi, did you change the jets on each burner and take out or change the spring in the regulator? The way it works is the purge cycle is first then the hot surface ignitor, when this proves the gas valve will open. Also when you change the burner to LP the electronics controller is supposed to be changed to a 100% shut down. If it is new enough it will have a LED light on the circuit board that flashes. Bright/dim is OK. The other flashes (like--3flashes --space 3 flashes means something don working. You have to look at the book to see. Don
    chopchop's Avatar
    chopchop Posts: 2, Reputation: 1
    New Member
     
    #3

    Nov 17, 2007, 04:06 PM
    Okay. Also I noticed that the when adjusting the pressure valve thing one side will burn how its suppose to and the other (where the igniter is) it still is the yellow flame. It seems that either enough gas is not getting through or the igniter will not light the lp gas
    T-Top's Avatar
    T-Top Posts: 1,871, Reputation: 100
    Ultra Member
     
    #4

    Nov 17, 2007, 07:04 PM
    Did you replace the burner orifices with the right ones, what is the manifold pressure after the burners are lit?

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Goodman furnace do not work [ 1 Answers ]

I have a Goodman furnace. The combustion air blower works but it will not ignite. It has an electronic ignition.

Goodman furnace do not work [ 1 Answers ]

Gas valve does not open . Light on board blinks one time. Please help me find solution.

Goodman furnace [ 2 Answers ]

My Goodman furnace will light and then go out. This will occur 3 times, then will quit running. The control board blinks 1 time and tells me to Check Gas flow, gas pressure, gas valve, and flame sensor. It seems to have gas going to the valve. Could this be a bad gas valve? Or a bad Flame...


View more questions Search