View Full Version : Coleman evcon furnace pressure switch failed to close
 
 karmathedog
May 24, 2010, 07:13 PM
My Coleman Evcon furnace will not heat.  I took off the cover and saw a red light flash three times indicating pressure switch failed to close.  I blew into both ends of the rubber tube.  I noticed a click as I blew in the direction of the pressure switch and another click as I ceased blowing.  Other than that, I am out of ideas.  Thanks.
 wmproop
May 24, 2010, 07:22 PM
Make sure the rubber hose doesn`t have any holes or cracks and that it fits tight on both end connections
 karmathedog
May 24, 2010, 07:26 PM
Thanks for responding wmproop.  The hose is in good shape and the connections are tight.
 Joshdta
May 25, 2010, 05:39 AM
Take the vent motor out and check for a blockage, birds or dirt.