Ask Me Help Desk

Ask Me Help Desk (https://www.askmehelpdesk.com/forum.php)
-   Plumbing (https://www.askmehelpdesk.com/forumdisplay.php?f=259)
-   -   Under the counter drain vent (https://www.askmehelpdesk.com/showthread.php?t=369585)

  • Jun 27, 2009, 08:20 AM
    b44m16c10
    Under the counter drain vent
    What is a under the counter air vent ? How is it installed ? What is the use of this item ?
  • Jun 27, 2009, 08:39 AM
    ballengerb1

    Are you asking about an air admittance valve (AAV) ? If so, install on the horizontal lateral line between the wall and the trap. An AAV is not going to work for decades so it must be accessible. All fixture need a trap and traps need a vent to allow air to enter the system otherwise water would not drain properly. To see how water drains without a trap turn a pop bottle upside down and watch how it chugs
  • Jun 27, 2009, 08:48 AM
    b44m16c10
    Quote:

    Originally Posted by ballengerb1 View Post
    Are you asking about an air admittance valve (AAV) ? If so, install on the horizontal lateral line between the wall and the trap. An AAV is not going to work for decades so it must be accessible. All fixture need a trap and traps need a vent to allow air to enter the system otherwise water would not drain properly. To see how water drains without a trap turn a pop bottle upside down and watch how it chugs

    Thank you for your answer on this matter it will be put to good use THANKS
  • Jun 27, 2009, 11:58 AM
    speedball1
    1 Attachment(s)
    Quote:

    Originally Posted by b44m16c10 View Post
    What is a under the counter air vent ? How is it installed ? What is the use of this item ?

    A under the counter air vent or AAV/ Air admittance Vent(see image) takes the place of a regular vent through the roof. It's mounted just downstream from the trap. Do you need more information? Regards, tom